<?xml version="1.0" ?>
<document version="1.8" entity_encoding="single">
  <page number="1">
    <text>**UNDER CONSTRUCTION**

REMOVABLE APPLIANCES

Dr Daniel Fernandes - Orthodontics
University of Western Australia - Dental School</text>
    <formatted_text>**UNDER CONSTRUCTION**

Dr Daniel Fernandes - Orthodontics

University of Western Australia - Dental School</formatted_text>
  </page>
  <page number="2">
    <text>What You Need to Know
• Why use a removable appliance
• Who is involved in fabricating a removable appliance
• Sequence of events in fabrication
• Ideal properties of a removable appliance
• Advantages and limitations of removable appliances
• Principles of design
• Communication
• Wire bending</text>
    <formatted_text>What You Need to Know

- Why use a removable appliance
- Who is involved in fabricating a removable appliance
- Sequence of events in fabrication
- Ideal properties of a removable appliance
- Advantages and limitations of removable appliances
- Principles of design
- Communication
- Wire bending</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:15:40" confidence="6" anchor="Communication - Wire bending">
- ==The active, retaining, stabilizing, and anchorage components of a removable appliance.==
- ==How appliance design affects tooth movement.==
- ==Common design and fabrication problems.==
- ==The properties and handling of stainless steel wire.==
- ==Basic wire-bending rules and the appropriate use of pliers.==
&gt; [!note] Lecturer — Practical Wire Bending
&gt; The lecture was followed by practical wire-bending work in the CSSL.
&gt;
&gt; - Students were expected to apply their previous experience with wire diameter, bending, springs, and appliance construction.</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="0,9,236,939" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>A 3D rendered graphic featuring a yellow hard hat resting on top of large, blocky orange letters that appear to spell 'CONSTR'. The image has a bright yellow background and is designed with a glossy, digital aesthetic.</description>
      </img>
      <img order="1" bbox="886,642,980,998" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>A cartoon-style illustration of a male handyman or repair worker wearing a tool belt and holding a wrench.</description>
      </img>
    </images>
  </page>
  <page number="3">
    <text>What You Need to Know
• Why use a removable appliance
• Who is involved in fabricating a removable appliance
• Sequence of events in fabrication
• Ideal properties of a removable appliance
• Advantages and limitations of removable appliances
• Principles of design
• Communication
• Wire bending</text>
    <formatted_text>What You Need to Know

- Why use a removable appliance
- Who is involved in fabricating a removable appliance
- Sequence of events in fabrication
- Ideal properties of a removable appliance
- Advantages and limitations of removable appliances
- Principles of design
- Communication
- Wire bending</formatted_text>
    <images>
      <img order="0" bbox="0,10,236,936" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>A graphic illustration featuring a yellow hard hat resting on top of large, three-dimensional orange text. The visible letters appear to be fragments of the words &quot;CONSTRUCTION&quot; or similar.</description>
      </img>
      <img order="1" bbox="875,635,972,997" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>A 3D rendered cartoon character of a man wearing a tool belt and holding an object, serving as decorative artwork.</description>
      </img>
    </images>
  </page>
  <page number="4">
    <text>Why use a removable appliance

*   Simple tipping movements
*   Moving only a few teeth at a time
*   Less chair-time required
*   Relatively cheap; no stock needed
*   Oral hygiene is easier
*   Damaged appliance is readily removed</text>
    <formatted_text>- Simple tipping movements
- Moving only a few teeth at a time
- Less chair-time required
- Relatively cheap; no stock needed
- Oral hygiene is easier
- Damaged appliance is readily removed</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:11:26" confidence="5" anchor="Less chair-time required - Relatively cheap; no stock needed - Oral hygiene is e">
- ==Follow-up, activation, and assessment of progress are relatively straightforward.==
- ==The patient should contact the dentist and bring a damaged appliance in for repair or adjustment.==
- ==A removable appliance can be used as a passive retainer or space retainer.==
- ==Space can sometimes be regained using springs.==
- ==Acrylic can be modified to provide a flat anterior bite plane.==
- ==In growing children, a removable appliance can address overbite while avoiding a lower appliance.==</insert>
    </audio_inserts>
  </page>
  <page number="5">
    <text>What You Need to Know
• Why use a removable appliance
• Who is involved in fabricating a removable appliance
• Sequence of events in fabrication
• Ideal properties of a removable appliance
• Advantages and limitations of removable appliances
• Principles of design
• Communication
• Wire bending</text>
    <formatted_text>- Why use a removable appliance
- Who is involved in fabricating a removable appliance
- Sequence of events in fabrication
- Ideal properties of a removable appliance
- Advantages and limitations of removable appliances
- Principles of design
- Communication
- Wire bending</formatted_text>
    <images>
      <img order="0" bbox="0,0,238,973" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>A 3D graphic illustration of a yellow hard hat resting on large, blocky text against an orange background.</description>
      </img>
    </images>
  </page>
  <page number="6">
    <text>Who is involved in fabricating a removable appliance

• Dentist or Orthodontist
• Dental Technician</text>
    <formatted_text>- Dentist or Orthodontist
- Dental Technician</formatted_text>
    <audio_inserts count="4">
      <insert timestamp="00:08:01" confidence="4" anchor="- Dentist or Orthodontist - Dental Technician">

&gt; [!note] Lecturer — Team Communication
&gt; The dentist or specialist diagnoses the problem, establishes treatment objectives, plans the appliance, and communicates the required design.
&gt;
&gt; - The dental technician bends the wires, constructs the appliance, and follows the dentist’s design.
&gt; - A good working relationship is important because inadequate communication can produce an appliance that does not fit or does not create the intended movement.
</insert>
      <insert timestamp="00:07:14" confidence="3" anchor="- Principles of design - Communication - Wire bending  ## **Sequence of Events i">

&gt; [!note] Lecturer — Clinical Understanding
&gt; The clinician does not necessarily need to construct every appliance personally, but must understand how the appliance is designed and what each component can achieve.
&gt;
&gt; - The clinician must understand how the appliance is retained, how anchorage is obtained, how components are positioned, and how to identify errors before activation.
&gt; - The design must be communicated clearly to the technician.
</insert>
      <insert timestamp="00:08:48" confidence="3" anchor="### **Roles of the Dentist and Dental Technician**  | Dentist | Dental Technicia">

&gt; [!note] Lecturer — Laboratory Construction
&gt; The technician’s laboratory work extends beyond bending and attaching wires.
&gt;
&gt; - The technician constructs the acrylic baseplate, polymerizes the acrylic, trims and polishes the appliance, and returns it for clinical fitting and adjustment.
&gt; - The dentist also specifies the intended tooth movement, acrylic limits, and screw position, then fits and adjusts the completed appliance and activates springs or screws when necessary.
</insert>
      <insert timestamp="00:09:21" confidence="8" anchor="#### **Dental Technician**  - Soak casts → Dry casts → Apply separating medium  ">

&gt; [!note] Lecturer — Acrylic Construction
&gt; Acrylic is built using small increments of monomer and polymer, a method described as the salt-and-pepper technique.
&gt;
&gt; - The acrylic is polymerized in a pressure pot or another closed environment to produce a smoother surface with less roughness.
&gt; - Digital scanning changes the logistics but not the basic process: the technician can print a working model from the scan and construct the appliance on that model.
</insert>
    </audio_inserts>
  </page>
  <page number="7">
    <text>What You Need to Know
• Why use a removable appliance
• Who is involved in fabricating a removable appliance
• Sequence of events in fabrication
• Ideal properties of a removable appliance
• Advantages and limitations of removable appliances
• Principles of design
• Communication
• Wire bending</text>
    <formatted_text>- Why use a removable appliance
- Who is involved in fabricating a removable appliance
- Sequence of events in fabrication
- Ideal properties of a removable appliance
- Advantages and limitations of removable appliances
- Principles of design
- Communication
- Wire bending</formatted_text>
    <images>
      <img order="0" bbox="0,0,238,973" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>The figure shows a stylized 3D graphic of a yellow hard hat resting on large block letters spelling 'CONSTR' against an orange background.</description>
      </img>
    </images>
  </page>
  <page number="8">
    <text>&lt;table&gt;
  &lt;tr&gt;
    &lt;th&gt;&lt;u&gt;Dentist&lt;/u&gt;&lt;/th&gt;
    &lt;th&gt;&lt;u&gt;Dental Technician&lt;/u&gt;&lt;/th&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;Clinical findings&lt;br&gt;and cast analysis&lt;/td&gt;
    &lt;td&gt;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;Treatment plan&lt;/td&gt;
    &lt;td&gt;&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;Alginate impression&lt;/td&gt;
    &lt;td&gt;Pour cast&lt;/td&gt;
  &lt;/tr&gt;
&lt;/table&gt;</text>
    <formatted_text>| Dentist | Dental Technician |
| --- | --- |
| Clinical findings and cast analysis | |
| Treatment plan | |
| Alginate impression | Pour cast |</formatted_text>
  </page>
  <page number="9">
    <text>&lt;table&gt;
  &lt;tr&gt;
    &lt;th&gt;Dentist&lt;/th&gt;
    &lt;th&gt;Dental Technician&lt;/th&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;Appliance design&lt;/td&gt;
    &lt;td&gt;Bend wire elements&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;&lt;b&gt;communication&lt;/b&gt;&lt;/td&gt;
    &lt;td&gt;Attach wire elements to cast&lt;/td&gt;
  &lt;/tr&gt;
  &lt;tr&gt;
    &lt;td&gt;&lt;/td&gt;
    &lt;td&gt;Fill in undercuts&lt;/td&gt;
  &lt;/tr&gt;
&lt;/table&gt;</text>
    <formatted_text>| Dentist | Dental Technician |
| --- | --- |
| Appliance design | Bend wire elements |
| Communication | Attach wire elements to cast |
| | Fill in undercuts |</formatted_text>
  </page>
  <page number="10">
    <text># Sequence to follow to fabricate a removable appliance*

## Dentist

## Dental Technician

```mermaid
flowchart TD
    A[Soak casts] --&gt; B[Dry casts]
    B --&gt; C[Apply separating medium]
```</text>
    <formatted_text>#### Dentist

#### Dental Technician

- Soak casts → Dry casts → Apply separating medium</formatted_text>
  </page>
  <page number="11">
    <text/>
  </page>
  <page number="12">
    <text>Sequence to follow to fabricate a removable appliance *

Dentist
Adjust clasps and springs
Instruct and motivate patient
Monitor treatment

Dental Technician</text>
    <formatted_text>#### Dentist

- Adjust clasps and springs
- Instruct and motivate patient
- Monitor treatment

#### Dental Technician</formatted_text>
    <images>
      <img order="0" bbox="710,685,961,941" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>The image displays a 3D cartoon illustration of a blonde woman wearing a red shirt and brown pants, sleeping while leaning against a tree stump with her feet propped up on a log. The graphic includes 'Zzz' symbols floating above her head to indicate snoring or deep sleep.</description>
      </img>
    </images>
  </page>
  <page number="13">
    <text>What You Need to Know
• Why use a removable appliance
• Who is involved in fabricating a removable appliance
• Sequence of events in fabrication
• Ideal properties of a removable appliance
• Advantages and limitations of removable appliances
• Principles of design
• Communication
• Wire bending</text>
    <formatted_text>#### What You Need to Know

- Why use a removable appliance
- Who is involved in fabricating a removable appliance
- Sequence of events in fabrication
- Ideal properties of a removable appliance
- Advantages and limitations of removable appliances
- Principles of design
- Communication
- Wire bending</formatted_text>
    <images>
      <img order="0" bbox="0,0,238,973" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>A 3D graphic featuring a yellow construction hard hat resting on large, blocky text that partially reads 'CONSTR'. The image is set against a bright orange and yellow gradient background.</description>
      </img>
    </images>
  </page>
  <page number="14">
    <text>Ideal properties of a removable appliance *

• Simple
• Strong
• Good retention
• Allow spontaneous movements
• Long range of action</text>
    <formatted_text>- Simple
- Strong
- Good retention
- Allow spontaneous movements
- Long range of action</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:10:45" confidence="3" anchor="- Simple - Strong - Good retention - Allow spontaneous movements - Long range of">
- ==Wires should be strong enough not to break during repeated insertion and removal.==
- ==The appliance should tolerate repeated handling by the patient.==
- ==It should maintain activity between appointments, often for two or three weeks.==
- ==It should provide sufficient anchorage.==
- ==It should be compatible with the patient.==
- ==It should be capable of adjustment to the treatment requirements.==
- ==It should be sufficiently durable for normal use.==
- ==It should allow the patient to remove and insert it safely.==</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="1,0,239,986" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>The image shows a 3D rendering of a yellow construction hard hat resting on top of large, bold orange letters spelling out parts of the word 'CONSTRUCTION'. The background is a gradient of orange and yellow tones.</description>
      </img>
    </images>
  </page>
  <page number="15">
    <text>What You Need to Know
• Why use a removable appliance
• Who is involved in fabricating a removable appliance
• Sequence of events in fabrication
• Ideal properties of a removable appliance
• Advantages and limitations of removable appliances
• Principles of design
• Communication
• Wire bending</text>
    <formatted_text>- Why use a removable appliance
- Who is involved in fabricating a removable appliance
- Sequence of events in fabrication
- Ideal properties of a removable appliance
- Advantages and limitations of removable appliances
- Principles of design
- Communication
- Wire bending</formatted_text>
    <images>
      <img order="0" bbox="0,0,238,973" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>A graphic featuring a yellow construction hard hat resting on top of large, 3D orange text that partially spells out 'CONSTRUCTION'.</description>
      </img>
    </images>
  </page>
  <page number="16">
    <text>Advantages and limitations of removable appliances

Advantages:

*   Acrylic can be flattened to form a flat anterior bite plane or buccal capping
*   Useful as a passive retainer or space maintainer
*   Can be used to transfer forces to blocks of teeth
*   Can be removed for tooth brushing
*   Palatal coverage increases anchorage
*   Can be used for overbite correction in growing children avoiding a lower appliance</text>
    <formatted_text>- Acrylic can be flattened to form a flat anterior bite plane or buccal capping
- Useful as a passive retainer or space maintainer
- Can be used to transfer forces to blocks of teeth
- Can be removed for tooth brushing
- Palatal coverage increases anchorage
- Can be used for overbite correction in growing children avoiding a lower appliance</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:12:05" confidence="6" anchor="- Can be used for overbite correction in growing children avoiding a lower appli">
- ==Acrylic can be adjusted according to the treatment requirement==
- ==Springs can be used to regain space==
- ==The acrylic provides a broad area of support and helps prevent unwanted tooth movement==
- ==Damage does not usually require an emergency appointment because the patient can remove the appliance==</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="0,288,240,929" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>A stylized graphic of a yellow construction hard hat resting on large, bold orange 3D text that appears to read 'UN' and 'ONSTR', likely part of the word 'CONSTRUCTION'.</description>
      </img>
    </images>
  </page>
  <page number="17">
    <text>Advantages and limitations of
removable appliances

Limitations:

• Difficult to move teeth that are unfavorably
inclined (tip and torque)
• Difficult to correct rotations
• Difficult to close residual spaces
• Difficult to achieve approximal contacts
• Lower appliances poorly tolerated</text>
    <formatted_text>- Difficult to move teeth that are unfavorably inclined (tip and torque)
- Difficult to correct rotations
- Difficult to close residual spaces
- Difficult to achieve approximal contacts
- Lower appliances poorly tolerated</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:13:08" confidence="2" anchor="Difficult to correct rotations - Difficult to close residual spaces - Difficult ">
- ==Only a limited number of teeth can be moved at one time.==
- ==Rotation is difficult because it requires force systems acting at more than one point.==
- ==Small residual spaces may be closed, but larger spaces are difficult to manage.==</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="1,280,239,938" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>The image shows a stylized 3D illustration of a yellow construction hard hat resting on large, blocky orange letters against a dark background. It is a generic graphic unrelated to the orthodontic subject matter of the slide.</description>
      </img>
    </images>
  </page>
  <page number="18">
    <text>Advantages and limitations of
removable appliances

Limitations:

• Appliances can be left out
• Only tipping movements possible
• Effects speech
• Good technicians required
• Intermaxillary traction not possible
• Inefficient for multiple individual tooth movements</text>
    <formatted_text>- Appliances can be left out
- Only tipping movements possible
- Affects speech
- Good technicians required
- Intermaxillary traction not possible
- Inefficient for multiple individual tooth movements</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:14:02" confidence="3" anchor="Appliances can be left out - Only tipping movements possible - Affects speech - ">
- ==Speech usually improves during the first weeks as the patient becomes accustomed to the appliance.==
- ==Patient motivation and cooperation are essential.==
- ==Anchorage and retention limit the amount of activation that can be used.==</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="1,282,240,935" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>A decorative graphic featuring a yellow construction hard hat resting on top of large, 3D orange letters spelling out 'CONSTRUCTION'.</description>
      </img>
    </images>
  </page>
  <page number="19">
    <text>What You Need to Know
• Why use a removable appliance
• Who is involved in fabricating a removable appliance
• Sequence of events in fabrication
• Ideal properties of a removable appliance
• Advantages and limitations of removable appliances
• Principles of design
• Communication
• Wire bending</text>
    <formatted_text>#### What You Need to Know

- Why use a removable appliance
- Who is involved in fabricating a removable appliance
- Sequence of events in fabrication
- Ideal properties of a removable appliance
- Advantages and limitations of removable appliances
- Principles of design
- Communication
- Wire bending</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:08:01" confidence="4" anchor="Advantages and limitations of removable appliances - Principles of design - Comm">
- ==Success depends on the type of movement required, the number of teeth being moved, and the amount of available space.==
- ==The strength and design of the anchorage and the retention of the appliance affect success.==
- ==Success also depends on the patient’s ability to wear and handle the appliance, accurate laboratory construction, and clear communication between dentist and technician.==</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="0,0,238,973" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>The image is a decorative graphic featuring large, 3D-style yellow text and a matching hard hat against an orange background. It serves as ornamental slide furniture rather than instructional content related to the topic.</description>
      </img>
    </images>
  </page>
  <page number="20">
    <text>Principles of design
Four components need to be considered

• Active Components (springs, bows, screws, elastics etc.)
• Retaining the appliance (clasps bows)
• Anchorage (palate, extraoral)
• Baseplate (palatal acrylic coverage)</text>
    <formatted_text>Four components need to be considered:

- Active Components (springs, bows, screws, elastics etc.)
- Retaining the appliance (clasps, bows)
- Anchorage (palate, extraoral)
- Baseplate (palatal acrylic coverage)</formatted_text>
    <images>
      <img order="0" bbox="1,0,239,976" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>A decorative graphic featuring a yellow hard hat resting on top of large, 3D orange text that appears to spell out 'CONSTRUCTION'.</description>
      </img>
    </images>
  </page>
  <page number="21">
    <text>**CONSTRUCTION**

**Active components**

*   Springs are the most commonly used active components
*   Labial movements of incisors
*   Palatal movement (retraction) of incisors
*   Mesial/Distal movements of incisors, canines, premolars and molars
*   Buccal movements of premolars and molars
*   Habit breaking
*   Bite opening (anterior bite plane)
*   Stabilizing components (proximal spur, occlusal rest)</text>
    <formatted_text>- Springs are the most commonly used active components
- Labial movements of incisors
- Palatal movement (retraction) of incisors
- Mesial/Distal movements of incisors, canines, premolars and molars
- Buccal movements of premolars and molars
- Habit breaking
- Bite opening (anterior bite plane)
- Stabilizing components (proximal spur, occlusal rest)</formatted_text>
  </page>
  <page number="22">
    <text>CONSTRUCTION

Labial movement of incisors

Z-spring
• A small double helices cantilever spring fabricated in 0.5-0.6mm wire
• Needs good anterior retention
• Activated by pulling spring 1-2mm from baseplate at a 45°

![](L8.2 Removable Appliances Construction_figures/img_3123eec095f49a0b.webp)
![](L8.2 Removable Appliances Construction_figures/img_72e856ad63849ef1.webp)</text>
    <formatted_text>#### Z-spring

- A small double helices cantilever spring fabricated in 0.5-0.6mm wire
- Needs good anterior retention
- Activated by pulling spring 1-2mm from baseplate at a 45°</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:16:51" confidence="2" anchor="- A small double helices cantilever spring fabricated in 0.5-0.6mm wire - Needs ">

&gt; [!note] Lecturer — Z-Spring Design
&gt; The Z-spring is used primarily for labial movement of incisors and correction of an anterior crossbite.
&gt;
&gt; - The acrylic and clasp design must leave space on the anterior labial side for the tooth to move.
&gt; - If the clasp is too close to the tooth, the spring cannot move the tooth effectively.
&gt; - Both helices may be activated, and the wire must be bent accurately before the appliance is placed in service.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="735,345,919,595" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_3123eec095f49a0b.webp">
        <description>Clinical photo: A close-up view of a metallic orthodontic appliance component, specifically a Z-spring, attached to a tooth. The spring features two helical loops forming a 'Z' shape and is used for labial movement of incisors.</description>
      </img>
      <img order="1" bbox="700,646,928,974" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_72e856ad63849ef1.webp">
        <description>Clinical photograph of a dental study model showing an orthodontic appliance with a Z-spring (double helix cantilever) positioned labially to the upper incisors, along with clasps engaging the posterior teeth.</description>
      </img>
    </images>
  </page>
  <page number="23">
    <text># CONSTRUCTION

## Labial movement of incisors

**Double cantilever spring**

*   designed to move more than one tooth labially
*   fabricated in 0.7-0.8mm wire
*   activated by pulling spring 1-2mm from baseplate at a 45°

![](L8.2 Removable Appliances Construction_figures/img_1068bd656d8959ec.webp)</text>
    <formatted_text>#### Double cantilever spring

- Designed to move more than one tooth labially
- Fabricated in 0.7-0.8mm wire
- Activated by pulling spring 1-2mm from baseplate at a 45°</formatted_text>
    <audio_inserts count="2">
      <insert timestamp="00:18:42" confidence="6" anchor="- Designed to move more than one tooth labially - Fabricated in 0.7-0.8mm wire -">

&gt; [!note] Lecturer — Double Cantilever
&gt; A double cantilever spring follows the same principle as the Z-spring but can produce broader movement involving the four incisors.
&gt;
&gt; - Its helices can be activated.
&gt; - A thicker wire may be needed because movement is required across more teeth, providing greater force.
</insert>
      <insert timestamp="00:20:00" confidence="4" anchor="##### Landin screw">

&gt; [!note] Lecturer — Landin Screw
&gt; The Landin screw uses a piston-like active component beneath the acrylic.
&gt;
&gt; - Activation moves the piston against the tooth intended to move labially.
&gt; - In an anterior crossbite, activation moves the incisor forward.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="606,435,978,938" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_1068bd656d8959ec.webp">
        <description>A clinical photograph shows a double cantilever spring orthodontic appliance fabricated from wire, mounted on the labial surface of upper incisors on a dental model. The device features two horizontal arms extending laterally with circular loops at each end and a central vertical U-shaped loop structure, designed to move multiple teeth labially.</description>
      </img>
    </images>
  </page>
  <page number="24">
    <text># CONSTRUCTION

Labial movement of incisors

Screw
* Can be useful where retention is limited
* Incisors clasped for additional retention
* Bulky
* activated ¼ turn every 3-4 days

![](L8.2 Removable Appliances Construction_figures/img_338297ab25a6e391.webp)
![](L8.2 Removable Appliances Construction_figures/img_000b7f1b9ba9b427.webp)</text>
    <formatted_text>#### Screw

- Can be useful where retention is limited
- Incisors clasped for additional retention
- Bulky
- Activated ¼ turn every 3-4 days</formatted_text>
    <images>
      <img order="0" bbox="524,644,771,974" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_338297ab25a6e391.webp">
        <description>Clinical photograph showing an orthodontic appliance mounted on a dental cast of the maxillary arch. The device features a central screw mechanism (expansion screw) surrounded by wire clasps that engage multiple teeth, including incisors and molars.</description>
      </img>
      <img order="1" bbox="744,362,996,726" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_000b7f1b9ba9b427.webp">
        <description>Clinical photograph showing an intraoral appliance with a central expansion screw and clasps on the upper teeth.</description>
      </img>
    </images>
  </page>
  <page number="25">
    <text># CONSTRUCTION

## Labial movement of incisors

### Landin screw
*   Also called piston screw
*   Used to procline one incisor direction determined by placement of screw
*   activated turning with flat plastic about 1mm

![](L8.2 Removable Appliances Construction_figures/img_34f31335ac9bee5e.webp)
![](L8.2 Removable Appliances Construction_figures/img_58b25875358ebcfa.webp)
![](L8.2 Removable Appliances Construction_figures/img_96a61f1534452b8b.webp)
![](L8.2 Removable Appliances Construction_figures/img_2f895528852e5326.webp)</text>
    <formatted_text>#### Landin screw

- Also called piston screw
- Used to procline one incisor; direction determined by placement of screw
- Activated by turning with flat plastic about 1mm</formatted_text>
    <images>
      <img order="0" bbox="601,364,757,589" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="diagram" path="L8.2 Removable Appliances Construction_figures/img_34f31335ac9bee5e.webp">
        <description>A schematic line drawing illustrating a Landin screw (piston screw) positioned against the labial surface of an incisor to demonstrate its use in proclining the tooth. The diagram shows the threaded body and knurled head of the screw engaging with the curved outline of the tooth root and crown.</description>
      </img>
      <img order="1" bbox="788,366,962,589" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="diagram" path="L8.2 Removable Appliances Construction_figures/img_58b25875358ebcfa.webp">
        <description>A schematic line drawing illustrates the placement of a Landin screw (piston screw) within an appliance, positioned between two tooth outlines. An arrow indicates the direction of force or movement exerted by the screw, demonstrating how it is used to procline an incisor.</description>
      </img>
      <img order="2" bbox="549,671,793,978" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_96a61f1534452b8b.webp">
        <description>Clinical photograph showing a dental study model fitted with an orthodontic appliance. A Landin screw (piston screw) is visible in the anterior region, connected to wire loops extending towards the incisors to facilitate labial movement.</description>
      </img>
      <img order="3" bbox="807,675,998,983" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_2f895528852e5326.webp">
        <description>Clinical photo: A close-up view of a threaded metallic orthodontic screw (Landin screw) attached to the labial surface of an upper incisor tooth. The device features a piston-like mechanism with a small protruding shaft, illustrating the hardware used for moving teeth.</description>
      </img>
    </images>
  </page>
  <page number="26">
    <text>CONSTRUCTION

Palatal movement (retraction) of incisors

Labial Bow

• Conventional labial bow can be too stiff
for active overjet reduction

• 0.7-0.8mm wire

![](L8.2 Removable Appliances Construction_figures/img_9b024caa4b4af078.webp)</text>
    <formatted_text>#### Labial Bow

- Conventional labial bow can be too stiff for active overjet reduction
- 0.7-0.8mm wire</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:21:13" confidence="3" anchor="- Conventional labial bow can be too stiff for active overjet reduction - 0.7-0.">

&gt; [!note] Lecturer — Labial Bow
&gt; A labial bow can act passively as a retainer or be activated to retract incisors and close residual spaces.
&gt;
&gt; - It extends from approximately the middle of the canine toward the distal region and should contact the incisors.
&gt; - Adequate acrylic anchorage is required before the bow is activated.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="523,582,978,973" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_9b024caa4b4af078.webp">
        <description>Clinical photo: A close-up view of the upper anterior teeth fitted with a conventional labial bow appliance. The wire component is shown spanning across the facial surfaces of the incisors, illustrating the device described in the text.</description>
      </img>
    </images>
  </page>
  <page number="27">
    <text># CONSTRUCTION

## Palatal movement (retraction) of incisors

### Labial Bow Modifications

*   Added wire to increase the range of the wire 0.7-0.8mm wire
*   Roberts retractor
    *   0.5mm wire with sheathed tubing distal to the helices
    *   Useful to retract proclined incisors
    *   Need adequate sulcus depth
    *   Followed by Hawley retainer

Tubing

![](L8.2 Removable Appliances Construction_figures/img_6dddae70b122c74f.webp)
![](L8.2 Removable Appliances Construction_figures/img_5cbf6948f8dd743a.webp)</text>
    <formatted_text>#### Labial Bow Modifications

- Added wire to increase the range of the wire (0.7-0.8mm wire)
- Roberts retractor
  - 0.5mm wire with sheathed tubing distal to the helices
  - Useful to retract proclined incisors
  - Need adequate sulcus depth
  - Followed by Hawley retainer

Tubing</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:22:28" confidence="4" anchor="- 0.5mm wire with sheathed tubing distal to the helices - Useful to retract proc">

&gt; [!note] Lecturer — Roberts Retractor
&gt; The thinner Roberts retractor wire increases resilience and range of movement but is easier for the patient to overbend during insertion and removal.
&gt;
&gt; - The patient must be instructed carefully in insertion and removal.
&gt; - If the wire is overbent, the retractor may no longer be active.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="656,327,926,624" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_6dddae70b122c74f.webp">
        <description>Clinical photo showing a Roberts retractor appliance attached to the maxillary teeth. The device consists of wire loops and tubing positioned anteriorly to retract proclined incisors, as described in the accompanying text.</description>
      </img>
      <img order="1" bbox="656,651,931,948" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_5cbf6948f8dd743a.webp">
        <description>Clinical intraoral photograph showing a Roberts retractor appliance in the maxillary arch, with wire loops engaging the first molars and tubing visible on the buccal aspect.</description>
      </img>
    </images>
  </page>
  <page number="28">
    <text>**CONSTRUCTION**

Palatal movement (retraction) of incisors

&lt;u&gt;Elastics&lt;/u&gt;

*   Popular as less visible to retract to reduce overjet
*   Can convert labial bow and bend hooks adjacent to canines
*   5/8&quot; 3.5 oz elastics
*   Need to trim palatal of base plate

Baseplate trimmed
Elastic
Labial bow cut and bent

![Baseplate trimmed Elastic Labial bow cut and bent](L8.2 Removable Appliances Construction_figures/img_e87dd23a0fb1f6d6.webp)</text>
    <formatted_text>#### Elastics

- Popular as less visible to retract to reduce overjet
- Can convert labial bow and bend hooks adjacent to canines
- 5/8&quot; 3.5 oz elastics
- Need to trim palatal of base plate

*Baseplate trimmed; elastic; labial bow cut and bent.*</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:23:46" confidence="4" anchor="- Popular as less visible to retract to reduce overjet - Can convert labial bow ">

&gt; [!note] Lecturer — Elastic Retraction
&gt; A clasp with a distal bend provides the point from which an intraoral elastic is stretched to retract the incisors.
&gt;
&gt; - The patient must be taught correct placement and followed closely.
&gt; - If the elastic slips or is placed incorrectly, it can injure soft tissues or create problems for the appliance and treatment.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="606,638,959,955" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="figure" path="L8.2 Removable Appliances Construction_figures/img_e87dd23a0fb1f6d6.webp" caption="Baseplate trimmed Elastic Labial bow cut and bent">
        <description>A clinical photograph showing an orthodontic appliance in the mouth, featuring a labial bow that has been cut and bent to form hooks for elastic attachment. Green arrows point to specific components, identifying the trimmed baseplate and the elastic band stretched across the arch.</description>
      </img>
    </images>
  </page>
  <page number="29">
    <text># CONSTRUCTION

Mesial/distal movement of incisors, canines, premolars and molars

Palatal Finger Spring
*   Activation half a tooth width
*   0.5mm wire

![](L8.2 Removable Appliances Construction_figures/img_96acc732e89596e9.webp)
![](L8.2 Removable Appliances Construction_figures/img_bbb1431c5a693e43.webp)</text>
    <formatted_text>#### Palatal Finger Spring

- Activation half a tooth width
- 0.5mm wire</formatted_text>
    <images>
      <img order="0" bbox="387,642,665,967" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_96acc732e89596e9.webp">
        <description>Clinical photo of a removable orthodontic appliance featuring a wire component with a looped tip, identified as a Palatal Finger Spring.</description>
      </img>
      <img order="1" bbox="733,639,973,968" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="figure" path="L8.2 Removable Appliances Construction_figures/img_bbb1431c5a693e43.webp">
        <description>A close-up photograph showing a bent wire orthodontic spring attached to a dental model. The spring features a central vertical section and a lower looped structure, positioned against the palatal surfaces of the teeth.</description>
      </img>
    </images>
  </page>
  <page number="30">
    <text>CONSTRUCTION

Mesial/distal movement of incisors, canines,
premolars and molars

Buccal Canine Retractor

• 0.7mm wire in a tube
• 1.0mm gives optimal retraction force


![TUBING](L8.2 Removable Appliances Construction_figures/img_8aeb2a1f27d4360d.webp)</text>
    <formatted_text>#### Buccal Canine Retractor

- 0.7mm wire in a tube
- 1.0mm gives optimal retraction force</formatted_text>
    <images>
      <img order="0" bbox="504,536,995,957" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_8aeb2a1f27d4360d.webp" caption="TUBING">
        <description>Clinical intraoral photograph showing a buccal canine retractor appliance in place on the upper teeth. A green arrow points to the metal tubing component of the wire assembly, while a red arrow indicates the canine tooth being retracted.</description>
      </img>
    </images>
  </page>
  <page number="31">
    <text>CONSTRUCTION

Mesial/distal movement of incisors, canines,
premolars and molars

Open Screw

• Used to CLOSE space
• 1 adjustment per week =
(0.25mm space closure)

![](L8.2 Removable Appliances Construction_figures/img_8fef9d2d7020b22d.webp)
![](L8.2 Removable Appliances Construction_figures/img_cc78102b1cd7c21c.webp)</text>
    <formatted_text>#### Open Screw

- Used to CLOSE space
- 1 adjustment per week = (0.25mm space closure)</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:28:54" confidence="3" anchor="- Used to CLOSE space - 1 adjustment per week = (0.25mm space closure)">

&gt; [!note] Lecturer — Open Screw
&gt; Each turn of the central jack screw produces approximately 0.25 mm of opening, so four activations produce approximately 1 mm.
&gt;
&gt; - Screw position determines the movement produced.
&gt; - A centrally positioned screw can also be used for maxillary expansion.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="413,683,680,935" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="figure" path="L8.2 Removable Appliances Construction_figures/img_8fef9d2d7020b22d.webp">
        <description>This is a close-up photograph of an orthodontic open coil spring mechanism, likely part of a fixed appliance. The device features a central threaded screw surrounded by helical coils, attached to metal brackets on either side, illustrating the hardware used for space closure as described in the text.</description>
      </img>
      <img order="1" bbox="726,683,985,973" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_cc78102b1cd7c21c.webp">
        <description>Clinical photograph showing a dental appliance with an open coil spring positioned between teeth, indicated by a large red arrow. The setup illustrates the use of an open screw mechanism for closing space during orthodontic treatment.</description>
      </img>
    </images>
  </page>
  <page number="32">
    <text># CONSTRUCTION

Mesial/distal movement of incisors, canines, premolars and molars

**&lt;u&gt;Small Slow Expansion Screw&lt;/u&gt;**

*   Used to OPEN space
*   1-2 adjustments per week = (0.25-0.5mm space opening)

![](L8.2 Removable Appliances Construction_figures/img_5650f33b55a83b23.webp)
![](L8.2 Removable Appliances Construction_figures/img_15652d2b2193e386.webp)</text>
    <formatted_text>#### Small Slow Expansion Screw

- Used to OPEN space
- 1-2 adjustments per week = (0.25-0.5mm space opening)</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:30:36" confidence="5" anchor="- Used to OPEN space - 1-2 adjustments per week = (0.25-0.5mm space opening)">

&gt; [!note] Lecturer — Slow Expansion
&gt; Slow activation is necessary because the appliance depends on clasp retention and acrylic anchorage.
&gt;
&gt; - Even an appliance with four Adams clasps requires gradual activation.
&gt; - Two activations produce 0.5 mm of opening in the screw, corresponding to approximately 0.25 mm on each side.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="489,596,720,955" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_5650f33b55a83b23.webp">
        <description>Clinical photo of a small slow expansion screw appliance mounted on a dental model, showing the central jackscrew mechanism and wire clasps.</description>
      </img>
      <img order="1" bbox="736,601,943,953" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_15652d2b2193e386.webp">
        <description>Clinical photo of a removable orthodontic appliance featuring a pink acrylic baseplate, an anterior bow wire, and two metal expansion screws located in the premolar regions.</description>
      </img>
    </images>
  </page>
  <page number="33">
    <text>CONSTRUCTION

Buccal movement of premolars and molars

T- Spring

• Used for single molar or premolar
• Requires good retention to resist displacing effect
• Activated by pulling wire away from acrylic at a 45° angle

![](L8.2 Removable Appliances Construction_figures/img_1b7961e7b8fc6854.webp)</text>
    <formatted_text>#### T-Spring

- Used for single molar or premolar
- Requires good retention to resist displacing effect
- Activated by pulling wire away from acrylic at a 45° angle</formatted_text>
    <images>
      <img order="0" bbox="636,603,975,974" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_1b7961e7b8fc6854.webp">
        <description>A clinical photograph of a transparent dental appliance fitted with wire clasps and a T-spring mechanism. The image illustrates the specific orthodontic device described in the text, showing how the spring is integrated into the acrylic base.</description>
      </img>
    </images>
  </page>
  <page number="34">
    <text># CONSTRUCTION

## Buccal movement of premolars and molars

&lt;u&gt;Molar spring&lt;/u&gt;

*   Used for buccal movement of molar
*   Activated by bending out towards buccal

![](L8.2 Removable Appliances Construction_figures/img_0ec0983ad56151ad.webp)
![](L8.2 Removable Appliances Construction_figures/img_79044e87451f91f8.webp)</text>
    <formatted_text>#### Molar spring

- Used for buccal movement of molar
- Activated by bending out towards buccal</formatted_text>
    <images>
      <img order="0" bbox="509,736,731,916" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="diagram" path="L8.2 Removable Appliances Construction_figures/img_0ec0983ad56151ad.webp">
        <description>A schematic line drawing illustrating a molar spring attached to the posterior teeth. The diagram shows the wire component bent out towards the buccal aspect of the molar, demonstrating the activation mechanism used for buccal movement.</description>
      </img>
      <img order="1" bbox="768,693,991,992" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_79044e87451f91f8.webp">
        <description>Clinical photo: A close-up view of a dental appliance featuring a wire spring mechanism attached to a tooth or model. A green arrow points upwards and outwards, indicating the direction of activation or movement (buccal) for the molar spring described in the slide text.</description>
      </img>
    </images>
  </page>
  <page number="35">
    <text># CONSTRUCTION

## Buccal movement of premolars and molars

### Expansion Appliance

*   Used for more than one tooth, for example correction of a crossbite by upper arch expansion
*   Activated by one adjustment 1-2 times per week
*   Posterior bite plate may be necessary to increase anchorage

![](L8.2 Removable Appliances Construction_figures/img_c3d7f28f94f4491f.webp)</text>
    <formatted_text>#### Expansion Appliance

- Used for more than one tooth, for example correction of a crossbite by upper arch expansion
- Activated by one adjustment 1-2 times per week
- Posterior bite plate may be necessary to increase anchorage</formatted_text>
    <images>
      <img order="0" bbox="620,443,996,998" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_c3d7f28f94f4491f.webp">
        <description>A clinical photograph showing an upper dental stone model fitted with a fixed expansion appliance. The device consists of a central screw mechanism (jackscrew) embedded in the palatal area, connected by wire arms to metal bands or clasps encircling the posterior teeth on both sides.</description>
      </img>
    </images>
  </page>
  <page number="36">
    <text>CONSTRUCTION

Buccal movement of premolars and molars

Expansion Appliance

• Can also be used in the lower arch
• Activated by one adjustment 1-2 times per week
• Posterior bite plate may be necessary to increase anchorage
• Not as effective – limited to dental tipping

![](L8.2 Removable Appliances Construction_figures/img_31076d52d44cba50.webp)
![](L8.2 Removable Appliances Construction_figures/img_4e69302eb42dc48f.webp)</text>
    <formatted_text>#### Expansion Appliance

- Can also be used in the lower arch
- Activated by one adjustment 1-2 times per week
- Posterior bite plate may be necessary to increase anchorage
- Not as effective – limited to dental tipping</formatted_text>
    <images>
      <img order="0" bbox="682,435,884,690" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_31076d52d44cba50.webp">
        <description>Clinical photo: An occlusal view of a dental study cast showing an expansion appliance fitted to the posterior teeth. The device features wire clasps engaging the premolars and molars on both sides, connected by a central screw mechanism positioned behind the anterior teeth.</description>
      </img>
      <img order="1" bbox="684,709,882,973" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_4e69302eb42dc48f.webp">
        <description>Clinical photograph showing an occlusal view of a lower dental cast fitted with a wire expansion appliance. The device features loops over the posterior teeth and a central split in the anterior region, designed to facilitate buccal movement or tipping.</description>
      </img>
    </images>
  </page>
  <page number="37">
    <text>Types of expansion screws
• Symmetrical bilateral expansion screw
• Fan screw

Fan Screw
More expansion anterior/posterior as required

![This type gives equal expansion on activation](L8.2 Removable Appliances Construction_figures/img_537eb04a637ce3f3.webp)
![](L8.2 Removable Appliances Construction_figures/img_e3d50f2be4b09813.webp)
![](L8.2 Removable Appliances Construction_figures/img_f04704f927dae3b8.webp)
![Fan Screw More expansion anterior/posterior as required](L8.2 Removable Appliances Construction_figures/img_ef727c85b79deaff.webp)</text>
    <formatted_text>#### Types of expansion screws

- Symmetrical bilateral expansion screw
- Fan screw

Fan screw: more expansion anterior/posterior as required.</formatted_text>
    <images>
      <img order="0" bbox="368,390,531,621" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="figure" path="L8.2 Removable Appliances Construction_figures/img_537eb04a637ce3f3.webp" caption="This type gives equal expansion on activation">
        <description>Clinical photograph of a symmetrical bilateral expansion screw appliance, showing the central activation mechanism and bands on both sides. The device is positioned in the center of the dental arch to provide equal expansion on activation.</description>
      </img>
      <img order="1" bbox="545,390,754,621" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="figure" path="L8.2 Removable Appliances Construction_figures/img_e3d50f2be4b09813.webp">
        <description>A close-up photograph of a metallic orthodontic expansion screw mechanism. The device features a central threaded activation rod connecting two opposing arms, with visible adjustment components and serrated edges.</description>
      </img>
      <img order="2" bbox="368,685,530,929" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="figure" path="L8.2 Removable Appliances Construction_figures/img_f04704f927dae3b8.webp">
        <description>A clinical photograph of a symmetrical bilateral expansion screw appliance, characterized by two central activation screws and radiating arms. The device is designed to provide equal expansion on activation, as indicated by the symmetrical arrangement of the metal framework.</description>
      </img>
      <img order="3" bbox="556,687,748,931" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_ef727c85b79deaff.webp" caption="Fan Screw More expansion anterior/posterior as required">
        <description>A clinical photograph of an orthodontic appliance featuring a central screw mechanism and wire clasps. The device includes acrylic plates with a distinct V-shaped configuration in the center, corresponding to the fan screw design mentioned in the slide text.</description>
      </img>
    </images>
  </page>
  <page number="38">
    <text>Positioning the screw correctly

The screw has to be correct in 3 planes of space


![Correct](L8.2 Removable Appliances Construction_figures/img_939b609803c1d8f2.webp)
![Incorrect](L8.2 Removable Appliances Construction_figures/img_42767a8a7b78908c.webp)</text>
    <formatted_text>The screw has to be correct in 3 planes of space.</formatted_text>
    <images>
      <img order="0" bbox="348,413,610,782" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="diagram" path="L8.2 Removable Appliances Construction_figures/img_939b609803c1d8f2.webp" caption="Correct">
        <description>A schematic diagram showing a dental arch from an occlusal view with a central reference point marked by intersecting vertical and horizontal dashed lines. This illustrates the correct positioning of a screw or component relative to the midline and transverse axis.</description>
      </img>
      <img order="1" bbox="654,417,894,789" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="diagram" path="L8.2 Removable Appliances Construction_figures/img_42767a8a7b78908c.webp" caption="Incorrect">
        <description>Line drawing of a dental arch viewed from above, showing the upper teeth arranged in a horseshoe shape. A central vertical reference line bisects the arch and passes through the front teeth. In the center of the arch, an orthodontic screw is depicted with its long axis tilted diagonally relative to the midline, illustrating an incorrect positioning.</description>
      </img>
    </images>
  </page>
  <page number="39">
    <text>Positioning the screw correctly

The screw has to be correct in 3 planes of space

Correct

Incorrect
Would result in lifting of the appliance off the right side.</text>
    <formatted_text>The screw has to be correct in 3 planes of space.

- Correct
- Incorrect: would result in lifting of the appliance off the right side.</formatted_text>
  </page>
  <page number="40">
    <text>Positioning the screw correctly

The screw has to be correct in 3 planes of space

![Fig. 6.51 Correct](L8.2 Removable Appliances Construction_figures/img_a41b9e5fbb30cc82.webp)
![Incorrect](L8.2 Removable Appliances Construction_figures/img_be7ebda73cbb93ce.webp)</text>
    <formatted_text>The screw has to be correct in 3 planes of space.</formatted_text>
    <images>
      <img order="0" bbox="309,440,605,814" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="figure" path="L8.2 Removable Appliances Construction_figures/img_a41b9e5fbb30cc82.webp" caption="Fig. 6.51 Correct">
        <description>A schematic diagram illustrating the correct positioning of a fixation screw relative to a tooth root and bone surface. The image shows a black plate with three holes (representing the screw) placed at an angle, accompanied by a printed caption &quot;Fig. 6.51 Correct&quot;.</description>
      </img>
      <img order="1" bbox="643,433,949,827" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="diagram" path="L8.2 Removable Appliances Construction_figures/img_be7ebda73cbb93ce.webp" caption="Incorrect">
        <description>A schematic cross-section of a tooth and surrounding bone, illustrating the placement of a horizontal fixation device. The device is positioned within the bone but does not engage the tooth root, which is depicted as being outside the device's path.</description>
      </img>
    </images>
  </page>
  <page number="41">
    <text># CONSTRUCTION

Habit breaking crib(s)

A wire is bent to protrude from the appliance to discourage the child from placement of their digit

![](L8.2 Removable Appliances Construction_figures/img_d92aeb45dee99ecc.webp)
![](L8.2 Removable Appliances Construction_figures/img_1c81726f251bbbda.webp)</text>
    <formatted_text>A wire is bent to protrude from the appliance to discourage the child from placement of their digit.</formatted_text>
    <images>
      <img order="0" bbox="84,360,419,789" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_d92aeb45dee99ecc.webp">
        <description>Clinical photograph of a habit-breaking dental appliance, specifically a crib-style retainer. The device features a clear acrylic baseplate with a wire framework that includes protruding loops (cribs) designed to discourage digit placement.</description>
      </img>
      <img order="1" bbox="428,402,752,689" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_1c81726f251bbbda.webp">
        <description>A clinical photograph of a dental model showing a wire appliance fitted across the anterior teeth. The wire is bent into a series of loops or spikes that protrude from the surface, designed to physically discourage digit placement.</description>
      </img>
    </images>
  </page>
  <page number="42">
    <text># CONSTRUCTION

## Bite opening

&lt;u&gt;Anterior bite plane&lt;/u&gt;
• Correction in the vertical dimension

![CORRECT](L8.2 Removable Appliances Construction_figures/img_25416057a70c145a.webp)
![INCORRECT](L8.2 Removable Appliances Construction_figures/img_25254429c23429f3.webp)
![WITH GROOVE](L8.2 Removable Appliances Construction_figures/img_7fed8676f474999e.webp)
![WITH CAPPING](L8.2 Removable Appliances Construction_figures/img_c7a646642834d028.webp)</text>
    <formatted_text>#### Anterior bite plane

- Correction in the vertical dimension</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:37:02" confidence="5" anchor="- Correction in the vertical dimension">

&gt; [!note] Lecturer — Anterior Bite Plane
&gt; An anterior bite plane can reduce a deep overbite by contacting the lower incisors and separating the posterior teeth.
&gt;
&gt; - Posterior eruption may rotate the mandible clockwise.
&gt; - The acrylic should be approximately orthogonal to the lower incisors; if inclined, it may act as an inclined plane and procline the incisors instead of permitting eruption.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="235,484,392,916" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="figure" path="L8.2 Removable Appliances Construction_figures/img_25416057a70c145a.webp" caption="CORRECT">
        <description>A schematic cross-section of the anterior maxillary and mandibular teeth embedded in alveolar bone, illustrating an 'Anterior bite plane' (depicted as a grey shaded area) positioned between the upper and lower incisors to correct the vertical dimension.</description>
      </img>
      <img order="1" bbox="407,480,567,904" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="diagram" path="L8.2 Removable Appliances Construction_figures/img_25254429c23429f3.webp" caption="INCORRECT">
        <description>A schematic cross-section of the anterior teeth and supporting bone, illustrating an incorrect application of a bite plane. The diagram shows a shaded appliance positioned against the palatal surface of the upper incisors rather than engaging the lower incisal edges.</description>
      </img>
      <img order="2" bbox="575,474,740,916" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="diagram" path="L8.2 Removable Appliances Construction_figures/img_7fed8676f474999e.webp" caption="WITH GROOVE">
        <description>A sagittal line drawing of the temporomandibular joint showing the condyle, articular disc (stippled), and mandibular fossa. A distinct groove or notch is visible on the anterior surface of the articular eminence, illustrating a specific anatomical variation.</description>
      </img>
      <img order="3" bbox="748,479,925,910" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="figure" path="L8.2 Removable Appliances Construction_figures/img_c7a646642834d028.webp" caption="WITH CAPPING">
        <description>A sagittal cross-sectional diagram illustrating the temporomandibular joint (TMJ) and surrounding structures, specifically depicting the condyle seated within the glenoid fossa. The articular disc is shown interposed between the mandibular condyle and the temporal bone, with the upper posterior band appearing thickened or capped relative to the lower portion.</description>
      </img>
    </images>
  </page>
  <page number="43">
    <text># CONSTRUCTION

## Bite opening

**Posterior bite plane plane**

*   Correction in the vertical dimension
*   Temporarily open the bite so as to allow a tooth that is in crossbite to be proclined
*   Control the vertical development of the posterior teeth (can use attachments for headgear – extraoral traction)

![](L8.2 Removable Appliances Construction_figures/img_16ff215d4f8a5c4c.webp)
![](L8.2 Removable Appliances Construction_figures/img_5be3eaf180453f20.webp)</text>
    <formatted_text>#### Posterior bite plane

- Correction in the vertical dimension
- Temporarily open the bite so as to allow a tooth that is in crossbite to be proclined
- Control the vertical development of the posterior teeth (can use attachments for headgear – extraoral traction)</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:39:15" confidence="5" anchor="- Correction in the vertical dimension - Temporarily open the bite so as to allo">

&gt; [!note] Lecturer — Posterior Bite Plane
&gt; A posterior bite plane may be used in a hyperdivergent patient to control posterior tooth eruption.
&gt;
&gt; - Posterior encapsulation can prevent or limit eruption of the posterior teeth.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="511,689,706,943" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="diagram" path="L8.2 Removable Appliances Construction_figures/img_16ff215d4f8a5c4c.webp">
        <description>A schematic line drawing illustrating a posterior bite plane appliance. The diagram depicts the device from an occlusal perspective (showing four teeth) and a lateral perspective (showing two teeth), with a horizontal shaded band representing the flat plane surface separating the upper and lower dental arches.</description>
      </img>
      <img order="1" bbox="747,696,972,987" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="figure" path="L8.2 Removable Appliances Construction_figures/img_5be3eaf180453f20.webp">
        <description>Clinical photograph of a clear acrylic posterior bite plane appliance viewed from the occlusal surface. The device features raised blocks along the posterior arch to disocclude the anterior teeth, and metal wire clasps (retention arrows) are visible on the buccal aspects.</description>
      </img>
    </images>
  </page>
  <page number="44">
    <text>Stabilizing components

Proximal spur
• Used to hols space preventing teeth from drifting

Occlusal rest
• Adds stability to the appliance

![](L8.2 Removable Appliances Construction_figures/img_36bb3cfd5a3bb3ec.webp)
![](L8.2 Removable Appliances Construction_figures/img_d4bd61cb6a5d5aa3.webp)
![](L8.2 Removable Appliances Construction_figures/img_f6556047121bef7b.webp)</text>
    <formatted_text>#### Proximal spur

- Used to hold space preventing teeth from drifting

#### Occlusal rest

- Adds stability to the appliance</formatted_text>
    <images>
      <img order="0" bbox="600,408,775,616" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_36bb3cfd5a3bb3ec.webp">
        <description>A clinical photograph of a dental study model featuring a fixed orthodontic appliance with metal bands, archwires, and attachments. The image illustrates the components used in space maintenance or stabilization on the teeth.</description>
      </img>
      <img order="1" bbox="794,408,965,613" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_d4bd61cb6a5d5aa3.webp">
        <description>Clinical photo: A close-up view of a dental appliance in the mouth, showing metal clasps and wires stabilizing teeth.</description>
      </img>
      <img order="2" bbox="780,684,934,930" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="figure" path="L8.2 Removable Appliances Construction_figures/img_f6556047121bef7b.webp">
        <description>Clinical photograph showing a close-up of an intraoral appliance with a metal wire component resting on a tooth surface. The image illustrates the physical placement of an occlusal rest or proximal spur used to stabilize the device.</description>
      </img>
    </images>
  </page>
  <page number="45">
    <text>Retaining the appliance

&lt;u&gt;Retention = What holds appliance in the mouth&lt;/u&gt;

• No suction . . . Like full dentures
• Relies on mechanical retention
• That is placing a part of the appliance in an undercut
• Done by various clasps and labial bow
• A properly designed and constructed clasp should be passive and exert no force on the tooth except when the appliance is dislodged</text>
    <formatted_text>Retention = what holds the appliance in the mouth.

- No suction . . . like full dentures
- Relies on mechanical retention
- That is placing a part of the appliance in an undercut
- Done by various clasps and labial bow

&gt; A properly designed and constructed clasp should be passive and exert no force on the tooth except when the appliance is dislodged.</formatted_text>
  </page>
  <page number="46">
    <text>Retaining the appliance

Adams clasp

• Engages undercuts mesial and distal at the buccal surface

![](L8.2 Removable Appliances Construction_figures/img_e520607c9297268a.webp)
![](L8.2 Removable Appliances Construction_figures/img_ca5ba7d83721d30d.webp)
![](L8.2 Removable Appliances Construction_figures/img_d36375b8473ea200.webp)</text>
    <formatted_text>#### Adams clasp

- Engages undercuts mesial and distal at the buccal surface</formatted_text>
    <images>
      <img order="0" bbox="285,595,475,906" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_e520607c9297268a.webp">
        <description>Clinical photo: A close-up view of a tooth fitted with an Adams clasp, showing the wire engaging the buccal surface.</description>
      </img>
      <img order="1" bbox="492,594,722,905" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_ca5ba7d83721d30d.webp">
        <description>Clinical photo showing a close-up of an Adams clasp appliance fitted onto a tooth. The image displays the characteristic metal wire clasps engaging the buccal surface, with two arrowhead-like components visible on either side and a connecting bridge across the center.</description>
      </img>
      <img order="2" bbox="737,599,958,914" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_d36375b8473ea200.webp">
        <description>A close-up clinical photograph showing a metal Adams clasp engaged on the buccal surface of a tooth. The wire component is visible wrapping around the tooth, illustrating how it engages the undercuts at the mesial and distal aspects.</description>
      </img>
    </images>
  </page>
  <page number="47">
    <text>Retaining the appliance

Arrowhead clasp

• Engages undercuts interproximal
undercut

![](L8.2 Removable Appliances Construction_figures/img_c16ae0a1aa198242.webp)
![b](L8.2 Removable Appliances Construction_figures/img_bf52fe6c59920d95.webp)</text>
    <formatted_text>#### Arrowhead clasp

- Engages undercuts interproximal undercut</formatted_text>
    <images>
      <img order="0" bbox="302,562,522,922" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_c16ae0a1aa198242.webp">
        <description>Clinical photo showing a metal arrowhead clasp attached to the side of a white dental model. The clasp features a distinct triangular or arrow-shaped head that engages the surface, connected to a curved metal arm.</description>
      </img>
      <img order="1" bbox="634,567,929,915" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_bf52fe6c59920d95.webp" caption="b">
        <description>Clinical photograph showing an occlusal view of a dental arch fitted with a transparent retainer appliance. A black arrow points to the posterior region, indicating the specific area of interest for the 'Arrowhead clasp' described in the slide text.</description>
      </img>
    </images>
  </page>
  <page number="48">
    <text># Retaining the appliance

&lt;u&gt;&quot;C&quot; clasp&lt;/u&gt;

• Engages undercuts interproximal undercut

VERTICAL END

a

![HORIZONTAL END](L8.2 Removable Appliances Construction_figures/img_31f44052403cb69e.webp)
![a VERTICAL END](L8.2 Removable Appliances Construction_figures/img_70f29d0659062ca1.webp)</text>
    <formatted_text>#### &quot;C&quot; clasp

- Engages undercuts interproximal undercut

Vertical end</formatted_text>
    <images>
      <img order="0" bbox="388,489,615,888" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_31f44052403cb69e.webp" caption="HORIZONTAL END">
        <description>A clinical photograph showing a metal C-clasp attached to a tooth. The image illustrates the horizontal end of the clasp engaging the interproximal undercut.</description>
      </img>
      <img order="1" bbox="648,490,880,885" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_70f29d0659062ca1.webp" caption="a VERTICAL END">
        <description>A close-up photograph showing a dental cast with a metal C-clasp applied to the buccal surface of a molar. The image highlights the 'vertical end' or terminal portion of the clasp arm as it curves around the tooth structure.</description>
      </img>
    </images>
  </page>
  <page number="49">
    <text># Retaining the appliance

*   Engages undercuts interproximal
    undercut


![Delta clasp](L8.2 Removable Appliances Construction_figures/img_52f65934056db561.webp)</text>
    <formatted_text>- Engages undercuts interproximal undercut</formatted_text>
    <images>
      <img order="0" bbox="307,551,637,925" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_52f65934056db561.webp" caption="Delta clasp">
        <description>Clinical photograph showing an orthodontic appliance with a specific clasp design (Delta clasp) engaged on the lower teeth. A green arrow points to the interproximal area where the metal arm of the clasp engages the undercut between two premolars.</description>
      </img>
    </images>
  </page>
  <page number="50">
    <text>Retaining the appliance

Ball clasp

• Engages undercuts interproximal
undercut

![a](L8.2 Removable Appliances Construction_figures/img_7b843312dc1c5e48.webp)
![c](L8.2 Removable Appliances Construction_figures/img_b2d8002349436bb9.webp)</text>
    <formatted_text>#### Ball clasp

- Engages undercuts interproximal undercut</formatted_text>
    <images>
      <img order="0" bbox="380,541,604,940" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_7b843312dc1c5e48.webp" caption="a">
        <description>Clinical photo: A close-up view of a metal ball clasp engaging an interproximal undercut between two teeth.</description>
      </img>
      <img order="1" bbox="640,543,861,940" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="image" path="L8.2 Removable Appliances Construction_figures/img_b2d8002349436bb9.webp" caption="c"/>
    </images>
  </page>
  <page number="51">
    <text>Retaining the appliance

Variations of the Ball clasp
• Engage undercuts interproximal
undercut

Eyelet clasp and triangle clasps

![](L8.2 Removable Appliances Construction_figures/img_5ce5545d170752f0.webp)
![a](L8.2 Removable Appliances Construction_figures/img_ac352f35a84912e4.webp)
![b](L8.2 Removable Appliances Construction_figures/img_76b179c32d36aa56.webp)</text>
    <formatted_text>#### Variations of the Ball clasp

- Engage undercuts interproximal undercut

Eyelet clasp and triangle clasps</formatted_text>
    <images>
      <img order="0" bbox="316,630,511,974" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_5ce5545d170752f0.webp">
        <description>Clinical photo: A close-up of a dental arch showing a metal wire clasp (specifically an eyelet or triangle style variation) engaging the interproximal undercut between two posterior teeth. The appliance is shown seated on the teeth, illustrating the mechanism for retaining the removable partial denture.</description>
      </img>
      <img order="1" bbox="537,630,732,975" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_ac352f35a84912e4.webp" caption="a">
        <description>Clinical intraoral photograph showing a metal wire clasp engaged on the occlusal and buccal surfaces of posterior teeth, illustrating an eyelet or triangle-style clasp design used for retaining a removable dental appliance.</description>
      </img>
      <img order="2" bbox="763,632,955,971" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_76b179c32d36aa56.webp" caption="b">
        <description>Clinical close-up photograph showing a wire clasp assembly, specifically illustrating an eyelet or triangle clasp design engaging the surface of a tooth. The image depicts the metal retentive arm forming a looped configuration to utilize interproximal undercuts for retention.</description>
      </img>
    </images>
  </page>
  <page number="52">
    <text># Retaining the appliance

&lt;u&gt;Other clasps&lt;/u&gt;
- Engage undercuts interproximal undercut

&lt;u&gt;Townsend Clasp&lt;/u&gt;

&lt;u&gt;Other Clasp used when fixed appliances in place&lt;/u&gt;

![Townsend Clasp](L8.2 Removable Appliances Construction_figures/img_82164cf1870a9d2c.webp)
![Other Clasp used when fixed appliances in place](L8.2 Removable Appliances Construction_figures/img_3d5285b3c4f01598.webp)</text>
    <formatted_text>#### Other clasps

- Engage undercuts interproximal undercut

- Townsend Clasp
- Other clasp used when fixed appliances in place</formatted_text>
    <images>
      <img order="0" bbox="281,650,477,932" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_82164cf1870a9d2c.webp" caption="Townsend Clasp">
        <description>A close-up clinical photograph showing a metal wire clasp engaging the interproximal undercut between two teeth. The wire loops down from the contact point and curves around the cervical regions of adjacent teeth, demonstrating how the appliance is retained.</description>
      </img>
      <img order="1" bbox="713,709,961,979" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_3d5285b3c4f01598.webp" caption="Other Clasp used when fixed appliances in place">
        <description>Clinical photograph of a dental model showing a fixed orthodontic bracket on a molar tooth. A wire clasp is attached to the bracket and extends distally, curving downwards to engage an undercut area on the adjacent tooth surface.</description>
      </img>
    </images>
  </page>
  <page number="53">
    <text>**Anchorage**

&lt;u&gt;The resistance to unwanted tooth movement&lt;/u&gt;

*   When we exert force on a tooth, an equal and opposite force is placed on the appliance in the opposite direction.
*   This means the unwanted force can move the anchor teeth.
*   Therefore when we plan orthodontic tooth movement the reciprocal effects throughout the dental arches must be carefully analyzed, evaluated and controlled.
*   The aim is to maximize the desired tooth movement while minimizing the undesirable effects</text>
    <formatted_text>The resistance to unwanted tooth movement.

- When we exert force on a tooth, an equal and opposite force is placed on the appliance in the opposite direction.
- This means the unwanted force can move the anchor teeth.
- Therefore when we plan orthodontic tooth movement the reciprocal effects throughout the dental arches must be carefully analyzed, evaluated and controlled.
- The aim is to maximize the desired tooth movement while minimizing the undesirable effects.</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:25:54" confidence="3" anchor="- Therefore when we plan orthodontic tooth movement the reciprocal effects throu">

&gt; [!note] Lecturer — Molar Distalization
&gt; When moving a molar distally to regain space for a premolar, anchorage is especially important.
&gt;
&gt; - The upper arch permits greater palatal acrylic coverage, whereas the lower arch is limited by the tongue.
&gt; - A removable appliance generally cannot regain more than approximately 2 mm of space in this situation.
</insert>
    </audio_inserts>
  </page>
  <page number="54">
    <text># Anchorage

&lt;u&gt;Ways to improve anchorage&lt;/u&gt;

*   Incorporate as many teeth as possible to resist the desired movement
*   Maximize the coverage by the baseplate.
*   Correctly make active components so they work most efficiently (consider point of application, direction and the duration of forces)
*   Increase anchorage by the use of inter-maxillary force (elastics) or extra-oral force (headgear)</text>
    <formatted_text>#### Ways to improve anchorage

- Incorporate as many teeth as possible to resist the desired movement
- Maximize the coverage by the baseplate
- Correctly make active components so they work most efficiently (consider point of application, direction and the duration of forces)
- Increase anchorage by the use of inter-maxillary force (elastics) or extra-oral force (headgear)</formatted_text>
  </page>
  <page number="55">
    <text>Anchorage

Baseplate – can be made from:

1) Acrylic with a salt and pepper technique
Or
2) Plastic with a vacuum forming technique.

• Should be extended to maximize anchorage and thick enough to give sufficient strength to prevent fracture
• However should not be too thick as it does overly interfere with speech</text>
    <formatted_text>The baseplate can be made from:

1. Acrylic with a salt and pepper technique
2. Plastic with a vacuum forming technique

- Should be extended to maximize anchorage and thick enough to give sufficient strength to prevent fracture
- However should not be too thick as it does overly interfere with speech</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:09:21" confidence="5" anchor="1. Acrylic with a salt and pepper technique 2. Plastic with a vacuum forming tec">

&gt; [!note] Lecturer — Baseplate Construction
&gt; Construction includes blocking out undercuts, attaching wire components to the cast, applying separating medium, adding monomer and polymer in small increments, polymerizing the acrylic in a pressure pot or closed environment, and trimming and polishing the appliance.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="1,10,237,937" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>The image displays a 3D rendered yellow construction hard hat resting on top of large, blocky orange letters against a black and orange background.</description>
      </img>
    </images>
  </page>
  <page number="56">
    <text>**Communication**

&lt;u&gt;There needs to be good communication between the dentist and the technician to ensure the appliance is made correctly:&lt;/u&gt;

There are two ways to do this:
1) Draw directly onto the cast
2) Complete a prescription form (sheet)</text>
    <formatted_text>There needs to be good communication between the dentist and the technician to ensure the appliance is made correctly.

There are two ways to do this:

1. Draw directly onto the cast
2. Complete a prescription form (sheet)</formatted_text>
    <audio_inserts count="2">
      <insert timestamp="00:49:54" confidence="4" anchor="There are two ways to do this:  1. Draw directly onto the cast 2. Complete a pre">

&gt; [!note] Lecturer — Laboratory Communication
&gt; A general instruction such as “make a removable appliance to regain space” is not sufficient because many designs could achieve that objective.
&gt;
&gt; - Drawings, colour coding, digital-scan notes, photographs, or uploaded files can clarify the intended design more reliably than a clasp name alone.
</insert>
      <insert timestamp="00:51:15" confidence="2" anchor="Failure to adapt the acrylic to the occlusal surface.  Framework prevents erupti">

&gt; [!note] Lecturer — Design Failures
&gt; If retention is inadequate, activating a spring may dislodge the entire appliance instead of moving the intended tooth.
&gt;
&gt; - Other failures include a distorted or incorrectly bent clasp, an inaccurate model or impression, an obstructed spring, and insufficient space for the intended tooth movement.
</insert>
    </audio_inserts>
  </page>
  <page number="57">
    <text>**Communication**

&lt;u&gt;Draw on the cast:&lt;/u&gt;

INTERDENTAL SPUR OR STOPS

SCREW

CLASP

SPLIT BASEPLATE</text>
    <formatted_text>#### Draw on the cast

- Interdental spur or stops
- Screw
- Clasp
- Split baseplate</formatted_text>
  </page>
  <page number="58">
    <text>**Communication**

Fill in a prescription sheet:

![Double Helix Springs Expansion Screw Posterior Bite Pads (PBP)](L8.2 Removable Appliances Construction_figures/img_8be96ae6433ec078.webp)</text>
    <formatted_text>Fill in a prescription sheet.</formatted_text>
    <images>
      <img order="0" bbox="419,362,832,910" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="diagram" path="L8.2 Removable Appliances Construction_figures/img_8be96ae6433ec078.webp" caption="Double Helix Springs Expansion Screw Posterior Bite Pads (PBP)">
        <description>A schematic diagram illustrating the components of an orthodontic appliance, specifically a quad-helix or similar device. The drawing depicts a dental arch with wire springs and a central screw mechanism, annotated with labels pointing to specific parts.</description>
      </img>
    </images>
  </page>
  <page number="59">
    <text>CONSTRUCTION

Common problems in design and fabrication

Failure to adapt the acrylic to the occlusal surface

![](L8.2 Removable Appliances Construction_figures/img_20e13e42d86759fd.webp)
![](L8.2 Removable Appliances Construction_figures/img_aa9dd82afc93314c.webp)</text>
    <formatted_text>Failure to adapt the acrylic to the occlusal surface.</formatted_text>
    <images>
      <img order="0" bbox="188,558,510,869" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_20e13e42d86759fd.webp">
        <description>A clinical photograph showing a row of teeth with metal clasps or attachments visible on the buccal surfaces, illustrating an acrylic appliance. The image demonstrates the lack of adaptation of the material to the occlusal surface as described in the slide text.</description>
      </img>
      <img order="1" bbox="586,536,781,950" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_aa9dd82afc93314c.webp">
        <description>Clinical photograph showing a dental cast with a wire clasp assembly placed over the occlusal surfaces of posterior teeth. The image illustrates the fit of the metal framework against the tooth contours.</description>
      </img>
    </images>
  </page>
  <page number="60">
    <text>Common problems in design and fabrication

&lt;u&gt;Framework prevents eruption of a tooth&lt;/u&gt;

![](L8.2 Removable Appliances Construction_figures/img_538c0f3c0051907c.webp)
![](L8.2 Removable Appliances Construction_figures/img_9a4b03ec85f56b96.webp)</text>
    <formatted_text>Framework prevents eruption of a tooth.</formatted_text>
    <images>
      <img order="0" bbox="179,525,497,943" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="figure" path="L8.2 Removable Appliances Construction_figures/img_538c0f3c0051907c.webp">
        <description>A black-and-white radiograph showing a dental arch with a wire framework (likely an orthodontic appliance or retainer) positioned over the teeth. The image illustrates how the metal wires and loops of the framework sit in close proximity to the tooth structures, visually demonstrating the potential for the device to physically obstruct or prevent the eruption of a tooth.</description>
      </img>
      <img order="1" bbox="524,527,788,941" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_9a4b03ec85f56b96.webp">
        <description>A dental radiograph showing a wire orthodontic appliance loop positioned over the crown of an unerupted tooth. The image illustrates how the framework physically blocks the path of eruption for the underlying tooth.</description>
      </img>
    </images>
  </page>
  <page number="61">
    <text>CONSTRUCTION

Common problems in design and fabrication

Bridge of the Adams clasp is too large and may interfere with occlusion and be traumatic to the cheek

![](L8.2 Removable Appliances Construction_figures/img_03909596728f6683.webp)</text>
    <formatted_text>Bridge of the Adams clasp is too large and may interfere with occlusion and be traumatic to the cheek.</formatted_text>
    <images>
      <img order="0" bbox="228,544,576,976" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_03909596728f6683.webp">
        <description>Clinical photo showing a maxillary dental cast with a removable partial denture framework. The image illustrates the placement of an Adams clasp on a posterior tooth, specifically highlighting how the connecting bridge arches over the gingival tissue and adjacent teeth.</description>
      </img>
    </images>
  </page>
  <page number="62">
    <text>CONSTRUCTION

Common problems in design and fabrication

Interference with two aspects of design
• For example the labial bow will prevent retraction of the canine

![](L8.2 Removable Appliances Construction_figures/img_ee6e114453d7ea10.webp)</text>
    <formatted_text>Interference with two aspects of design:

- For example the labial bow will prevent retraction of the canine</formatted_text>
    <images>
      <img order="0" bbox="737,533,982,985" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_ee6e114453d7ea10.webp">
        <description>A close-up clinical photograph shows a wire orthodontic appliance fitted over teeth. A green arrow points to the vertical loop of the labial bow, illustrating its position relative to the canine tooth.</description>
      </img>
    </images>
  </page>
  <page number="63">
    <text># CONSTRUCTION

## Common problems in design and fabrication

### Failure to position the screw correctly

* For example the screw is placed vertically and will just displace the appliance


![a](L8.2 Removable Appliances Construction_figures/img_25141903f22b36ef.webp)
![b](L8.2 Removable Appliances Construction_figures/img_e68741ed8e2bd0c3.webp)</text>
    <formatted_text>#### Failure to position the screw correctly

- For example the screw is placed vertically and will just displace the appliance</formatted_text>
    <images>
      <img order="0" bbox="97,613,325,982" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_25141903f22b36ef.webp" caption="a">
        <description>A lateral cephalometric radiograph showing a patient wearing a removable orthodontic appliance with metal clasps and wires. A dark, cross-shaped object (likely a screw or marker) is superimposed over the central region of the appliance, illustrating its position relative to the teeth and jaw.</description>
      </img>
      <img order="1" bbox="342,611,570,981" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_e68741ed8e2bd0c3.webp" caption="b">
        <description>A photograph of a transparent orthodontic removable appliance with wire clasps and an expansion screw mechanism embedded in the midline. The image illustrates a common design failure where the screw is positioned incorrectly, causing it to displace the appliance rather than expand it.</description>
      </img>
    </images>
  </page>
  <page number="64">
    <text>**UNDER**
**CONSTRUCTION**

WIRE BENDING

J. Mike Razza Orthodontics
University of Western Australia - Dental School</text>
    <formatted_text>*Under construction*

J. Mike Razza Orthodontics
University of Western Australia - Dental School</formatted_text>
  </page>
  <page number="65">
    <text>What You Need to Know
• Why use a removable appliance
• Who is involved in fabricating a removable appliance
• Sequence of events in fabrication
• Ideal properties of a removable appliance
• Advantages and limitations of removable appliances
• Principles of design
• Communication
• Wire bending</text>
    <formatted_text>#### What You Need to Know

- Why use a removable appliance
- Who is involved in fabricating a removable appliance
- Sequence of events in fabrication
- Ideal properties of a removable appliance
- Advantages and limitations of removable appliances
- Principles of design
- Communication
- Wire bending</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:05:11" confidence="5" anchor="- Principles of design - Communication - Wire bending">

&gt; [!note] Lecturer — Wire Bending
&gt; Wire bending is necessary for constructing removable appliances.
&gt;
&gt; - Students should understand how wire diameter, spring design, activation, resilience, and repeated bending affect appliance performance.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="0,0,238,973" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>A decorative graphic featuring a yellow hard hat resting on top of large, 3D orange text against an orange background.</description>
      </img>
    </images>
  </page>
  <page number="66">
    <text>Wire Bending

Ideal properties of wire for removable appliances:

*   Strength to withstand deformation
*   Constant force over wide arch of deflection
*   High resilience (energy for tooth movement)
*   Biocompatible and environmentally stable
*   Formable so can bend into hooks
*   Joinable (weld or solder)
*   Low cost</text>
    <formatted_text>Ideal properties of wire for removable appliances:

- Strength to withstand deformation
- Constant force over wide arch of deflection
- High resilience (energy for tooth movement)
- Biocompatible and environmentally stable
- Formable so can bend into hooks
- Joinable (weld or solder)
- Low cost</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:55:47" confidence="7" anchor="- Formable so can bend into hooks - Joinable (weld or solder) - Low cost">

&gt; [!note] Lecturer — Wire Resilience
&gt; Resilience is the capacity of the wire to store elastic energy and release it over time.
&gt;
&gt; - Resilience can be increased by reducing wire thickness, increasing wire length, incorporating loops or helices, and using an appropriate spring design.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="1,17,237,931" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>The image displays a 3D graphic of a yellow construction hard hat resting on large, bold orange letters that partially spell out 'CONSTRUCTION'.</description>
      </img>
    </images>
  </page>
  <page number="67">
    <text>Wire Bending

What type of wire do we use?

18-8 Stainless steel:

• An alloy of Iron and Carbon
• 18-8 indicates there is 18%Chromium and 8% Nickel with 71% Iron and 0.15% Carbon
• Chromium forms an oxide layer which is in effect what makes stainless steel stainless</text>
    <formatted_text>What type of wire do we use?

#### 18-8 Stainless Steel

- An alloy of Iron and Carbon
- 18-8 indicates there is 18% Chromium and 8% Nickel with 71% Iron and 0.15% Carbon
- Chromium forms an oxide layer which is in effect what makes stainless steel stainless</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:57:40" confidence="5" anchor="- Chromium forms an oxide layer which is in effect what makes stainless steel st">

&gt; [!note] Lecturer — Nickel Sensitivity
&gt; Nickel stabilizes the austenitic phase, and austenitic stainless steel is suitable for wire bending.
&gt;
&gt; - Patients should be asked about reactions to earrings because nickel sensitivity may be relevant.
&gt; - Titanium-based wire may be considered for a patient who cannot tolerate nickel, although it is substantially more expensive.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="1,0,237,975" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>A decorative 3D illustration featuring a yellow hard hat resting on large, bold text that appears to read 'CONSTRUCTION'. The graphic uses an orange and yellow color scheme with black accents.</description>
      </img>
    </images>
  </page>
  <page number="68">
    <text>Wire Bending

Properties of Stainless steel:

• Large Modulus of Elasticity / High stiffness
• Resists deformation
• Produces high forces for small deflection
• Requires frequent activations</text>
    <formatted_text>Properties of Stainless Steel:

- Large Modulus of Elasticity / High stiffness
- Resists deformation
- Produces high forces for small deflection
- Requires frequent activations</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:56:01" confidence="5" anchor="- Large Modulus of Elasticity / High stiffness - Resists deformation - Produces ">

&gt; [!note] Lecturer — Stainless Steel Wire
&gt; Stainless steel is commonly used because it is relatively inexpensive and can be soldered to other stainless steel components.
&gt;
&gt; - Its stiffness means that wire design must be used to increase resilience.
&gt; - A thinner wire with additional loops can provide a greater range of deflection and lower force.
</insert>
    </audio_inserts>
  </page>
  <page number="69">
    <text>Wire Bending

Properties of Stainless steel:

• Work hardening
– The more the wire is bent the more its hardness increases
– Excessive bending will break the wire due to fatigue
– Therefore if it has taken many bends to adapt the wire start again as it may break in the mouth which will require a replacement appliance</text>
    <formatted_text>Properties of Stainless Steel:

#### Work Hardening

- The more the wire is bent the more its hardness increases
- Excessive bending will break the wire due to fatigue
- Therefore if it has taken many bends to adapt the wire, start again, as it may break in the mouth which will require a replacement appliance</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="01:03:03" confidence="4" anchor="- Therefore if it has taken many bends to adapt the wire, start again, as it may">

&gt; [!note] Lecturer — Work Hardening
&gt; Repeated bending creates microstructural changes called dislocations, making the wire harder and more brittle.
&gt;
&gt; - A spring should not be repeatedly bent, unbent, and rebent; corrections should be completed before the appliance is placed in service.
&gt; - Excessive work hardening may require a new impression or scan, appliance remaking, and additional clinical and laboratory procedures.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="1,0,239,983" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>The image displays a 3D graphic of a yellow construction hard hat resting on top of large, bold orange text that partially reads 'CONSTR'. This appears to be decorative clip art likely used as a visual metaphor for building or construction.</description>
      </img>
    </images>
  </page>
  <page number="70">
    <text>Wire Bending
Properties of Stainless steel:

Can be soldered

Stainless steel should never be heated to a point where it glows red hot (sensitive to heat in the range of 700-800°C)

1) It will loose its temper and become annealed, which significantly softens the wire.
2) The carbon and Chromium combine and are deposited at the grain boundaries causing the metal to become brittle with reduced resistance to corrosion.</text>
    <formatted_text>Properties of Stainless Steel:

#### Heat Sensitivity and Soldering

Can be soldered.

&gt; Stainless steel should never be heated to a point where it glows red hot (sensitive to heat in the range of 700-800°C).

1. It will lose its temper and become annealed, which significantly softens the wire.
2. The carbon and Chromium combine and are deposited at the grain boundaries, causing the metal to become brittle with reduced resistance to corrosion.</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="01:04:33" confidence="4" anchor="2. The carbon and Chromium combine and are deposited at the grain boundaries, ca">

&gt; [!note] Lecturer — Soldering Heat
&gt; Stainless steel can be joined using silver soldering, which melts at approximately 700°C.
&gt;
&gt; - The soldering procedure must be quick because excessive heating removes the mechanical effects of work hardening introduced during manufacture.
&gt; - An overheated piece should be discarded and replaced.
</insert>
    </audio_inserts>
  </page>
  <page number="71">
    <text>Wire Bending

BASIC WIRE BENDING RULES:

• Hold both ends as small cut-offs can fly across the room.

• If the cut-off is too short to hold, then place lab cutters against something to control the cut piece to ensure it doesn’t hit anyone.

• Wear safety glasses at all times.

![](L8.2 Removable Appliances Construction_figures/img_394c387425a975f1.webp)</text>
    <formatted_text>Basic Wire Bending Rules:

- Hold both ends, as small cut-offs can fly across the room.
- If the cut-off is too short to hold, then place lab cutters against something to control the cut piece to ensure it doesn't hit anyone.
- Wear safety glasses at all times.</formatted_text>
    <audio_inserts count="1">
      <insert confidence="1" anchor="- Hold both ends, as small cut-offs can fly across the room. - If the cut-off is">
- ==Ensure that wire ends are not sharp.==</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="829,147,996,365" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_394c387425a975f1.webp">
        <description>A close-up photograph showing a pair of hands holding a small, thin wire with a specialized tool, likely demonstrating a technique for bending or cutting the material.</description>
      </img>
    </images>
  </page>
  <page number="72">
    <text>Wire Bending

BASIC WIRE BENDING RULES:

• Pliers are used to hold the wire, like a vice.
• Do not use the pliers to apply force that bends the wire as it results in excessive wear and possible damage of the pliers.
• The forces to bend the wire applied by the fingers and thumb.</text>
    <formatted_text>Basic Wire Bending Rules:

- Pliers are used to hold the wire, like a vice.
- Do not use the pliers to apply force that bends the wire, as it results in excessive wear and possible damage of the pliers.
- The forces to bend the wire are applied by the fingers and thumb.</formatted_text>
  </page>
  <page number="73">
    <text>Wire Bending

Types of Pliers:
Adams Pliers or (Square jaw)
• Two square jaws terminating at a 1mm square tip
• Available in a number of sizes to bend wire from sizes light to heavy.
• Can be used to place torqueing bends.

![](L8.2 Removable Appliances Construction_figures/img_39784617dc29245a.webp)</text>
    <formatted_text>Types of Pliers:

#### Adams Pliers (Square Jaw)

- Two square jaws terminating at a 1mm square tip
- Available in a number of sizes to bend wire from light to heavy sizes
- Can be used to place torqueing bends</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="01:06:50" confidence="3" anchor="- Available in a number of sizes to bend wire from light to heavy sizes - Can be">

&gt; [!note] Lecturer — Adams Pliers
&gt; Adams pliers are appropriate for sharp-edged, square-shaped, angular, or square bends.
&gt;
&gt; - They should not be used to form loops or adjust the helices of a Z-spring because repeated corrections can increase work hardening at the same point and the risk of wire failure.
</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="757,186,986,511" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_39784617dc29245a.webp">
        <description>A close-up photograph showing the jaws of a pair of pliers, specifically featuring square-shaped tips that terminate in flat ends. This visual corresponds to the description of Adams Pliers (or Square jaw pliers) used for wire bending.</description>
      </img>
    </images>
  </page>
  <page number="74">
    <text>Wire Bending

Types of Pliers:

Loop or Spring
Forming pliers

*   One square one round jaw
*   Available in a number of sizes to bend wire from sizes light to heavy.
*   The stepping allows you to form uniform loops of various sizes.
*   Pressing too hard will leave nicks in the wire.</text>
    <formatted_text>Types of Pliers:

#### Loop or Spring Forming Pliers

- One square, one round jaw
- Available in a number of sizes to bend wire from light to heavy sizes
- The stepping allows you to form uniform loops of various sizes
- Pressing too hard will leave nicks in the wire</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="01:07:26" confidence="4" anchor="- The stepping allows you to form uniform loops of various sizes - Pressing too ">
- ==A 139 plier, with one square and one round tip, may be used depending on the required design.==</insert>
    </audio_inserts>
    <images>
      <img order="0" bbox="1,11,237,937" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="clipart">
        <description>A 3D graphic illustration featuring a yellow construction hard hat resting on top of large, bold text that partially spells out 'UNCONSTR' (likely part of the word 'UNCONSTRAINED'). The image uses an orange and black color scheme.</description>
      </img>
    </images>
  </page>
  <page number="75">
    <text>Wire Bending

Types of Pliers:

Wire Cutters

• Orthodontic wire cutters have a hardened tip to cut all materials easily.

![](L8.2 Removable Appliances Construction_figures/img_0f88a540799fc912.webp)</text>
    <formatted_text>Types of Pliers:

#### Wire Cutters

- Orthodontic wire cutters have a hardened tip to cut all materials easily.</formatted_text>
    <images>
      <img order="0" bbox="424,605,728,956" bbox_format="xyxy_norm_1000" bbox_origin="top_left" bbox_space="page" type="photo" path="L8.2 Removable Appliances Construction_figures/img_0f88a540799fc912.webp">
        <description>A close-up photograph of a pair of wire cutters, highlighting the hardened cutting tips and the pivot joint mechanism.</description>
      </img>
    </images>
  </page>
  <page number="76">
    <text/>
  </page>
  <page number="77">
    <text>At the end of this course you &lt;ins&gt;DO NOT&lt;/ins&gt; have the didactic knowledge or clinical skills to treat comprehensive orthodontic cases.</text>
    <formatted_text>At the end of this course you **DO NOT** have the didactic knowledge or clinical skills to treat comprehensive orthodontic cases.</formatted_text>
    <audio_inserts count="1">
      <insert timestamp="00:05:11" confidence="5" anchor="At the end of this course you **DO NOT** have the didactic knowledge or clinical">

&gt; [!note] Lecturer — Practical Expectations
&gt; Students are expected to understand the principles sufficiently to follow fabrication, recognize appropriate designs, identify construction errors, and communicate effectively with the dental technician.
&gt;
&gt; - They should also recognize problems with retention, anchorage, screw position, and wire bending, and apply wire-bending knowledge during practical work.
&gt; - Assistance with wire bending and appliance adjustments is available after the lecture and during practical sessions.
</insert>
    </audio_inserts>
  </page>
  <page number="78" origin="cases">
    <text>## Case: Removable appliance with Z-spring for lateral incisor crossbite

### Question

**Scenario:** A study model showing a removable orthodontic appliance designed to correct an anterior crossbite involving a lateral incisor.

**What's shown:** An appliance embedded in an acrylic plate featuring a Z-spring and a clasp on the adjacent tooth.

**Consider:** How the design of the clasp and spring allows for the planned tooth movement.


### Answer

**Observations:**
- The Z-spring is embedded in the acrylic plate.
- There is a clasp (hollow clasp) adjacent to the lateral incisor.
- Space is provided on the anterior and labial part for the lateral incisor to be inclined.

**Reasoning:** 
- To correct the anterior crossbite, the lateral incisor needs space to move labially.
- If the clasp is in close relation to the tooth, it blocks movement, so force must be applied labially with adequate space provided.
- The spring is fabricated with 0.5 or 0.6 mm wire to improve the range and resilience, allowing activation of both helices to change the position of the lateral incisor.

**Outcome:** The design allows for the correction of the lateral incisor's position in the anterior crossbite.

**Takeaway:** When designing a removable appliance for an anterior crossbite, ensure adequate labial space for tooth movement and use an appropriate wire gauge (0.5-0.6 mm) for spring resilience.

## Case: Double cantilever spring for incisor movement

### Question

**Scenario:** A clinical photograph showing a double cantilever spring on an orthodontic appliance.

**What's shown:** A spring design with helices that spans across the anterior teeth.

**Consider:** The indication for this spring design and the required wire modifications compared to a standard Z-spring.


### Answer

**Observations:**
- The design is a double cantilever spring.
- It spans across and considers all four incisors.

**Reasoning:** 
- This design achieves broader movement across multiple teeth (all four incisors).
- Because the movement is across more teeth, a thicker wire is needed to increase the amount of force delivered.

**Outcome:** The appliance achieves broader movement of the four incisors.

**Takeaway:** A double cantilever spring is used for broader anterior movement and requires a thicker wire to deliver the necessary increased force.

## Case: Expansion screws for retroclined central incisors

### Question

**Scenario:** An orthodontic appliance mounted on a model, featuring screws in the anterior part.

**What's shown:** An appliance with screws positioned in the anterior acrylic plate, adjacent to retroclined central incisors.

**Consider:** How the positioning and activation of the screws modulate the required tooth movement.


### Answer

**Observations:**
- The central incisors are retroclined.
- Screws are positioned in the anterior part of the acrylic plate.

**Reasoning:** 
- The screws can be positioned in different places to modulate the specific movement needed.
- Activating the screw increases the separation between the parts of the acrylic plate, applying force to move the incisors labially.

**Outcome:** The central incisors are moved labially to correct the retroclination.

**Takeaway:** Expansion screws offer a flexible technique where their placement modulates the specific direction and type of anterior tooth movement.
</text>
    <formatted_text>## Case: Removable appliance with Z-spring for lateral incisor crossbite

### Question

**Scenario:** A study model showing a removable orthodontic appliance designed to correct an anterior crossbite involving a lateral incisor.

**What's shown:** An appliance embedded in an acrylic plate featuring a Z-spring and a clasp on the adjacent tooth.

**Consider:** How the design of the clasp and spring allows for the planned tooth movement.


![](L8.2 Removable Appliances Construction_cases_attachments/img_72e856ad63849ef1.webp)
### Answer

**Observations:**
- The Z-spring is embedded in the acrylic plate.
- There is a clasp (hollow clasp) adjacent to the lateral incisor.
- Space is provided on the anterior and labial part for the lateral incisor to be inclined.

**Reasoning:** 
- To correct the anterior crossbite, the lateral incisor needs space to move labially.
- If the clasp is in close relation to the tooth, it blocks movement, so force must be applied labially with adequate space provided.
- The spring is fabricated with 0.5 or 0.6 mm wire to improve the range and resilience, allowing activation of both helices to change the position of the lateral incisor.

**Outcome:** The design allows for the correction of the lateral incisor's position in the anterior crossbite.

**Takeaway:** When designing a removable appliance for an anterior crossbite, ensure adequate labial space for tooth movement and use an appropriate wire gauge (0.5-0.6 mm) for spring resilience.

## Case: Double cantilever spring for incisor movement

### Question

**Scenario:** A clinical photograph showing a double cantilever spring on an orthodontic appliance.

**What's shown:** A spring design with helices that spans across the anterior teeth.

**Consider:** The indication for this spring design and the required wire modifications compared to a standard Z-spring.


![](L8.2 Removable Appliances Construction_cases_attachments/img_1068bd656d8959ec.webp)
### Answer

**Observations:**
- The design is a double cantilever spring.
- It spans across and considers all four incisors.

**Reasoning:** 
- This design achieves broader movement across multiple teeth (all four incisors).
- Because the movement is across more teeth, a thicker wire is needed to increase the amount of force delivered.

**Outcome:** The appliance achieves broader movement of the four incisors.

**Takeaway:** A double cantilever spring is used for broader anterior movement and requires a thicker wire to deliver the necessary increased force.

## Case: Expansion screws for retroclined central incisors

### Question

**Scenario:** An orthodontic appliance mounted on a model, featuring screws in the anterior part.

**What's shown:** An appliance with screws positioned in the anterior acrylic plate, adjacent to retroclined central incisors.

**Consider:** How the positioning and activation of the screws modulate the required tooth movement.


![](L8.2 Removable Appliances Construction_cases_attachments/img_000b7f1b9ba9b427.webp)
### Answer

**Observations:**
- The central incisors are retroclined.
- Screws are positioned in the anterior part of the acrylic plate.

**Reasoning:** 
- The screws can be positioned in different places to modulate the specific movement needed.
- Activating the screw increases the separation between the parts of the acrylic plate, applying force to move the incisors labially.

**Outcome:** The central incisors are moved labially to correct the retroclination.

**Takeaway:** Expansion screws offer a flexible technique where their placement modulates the specific direction and type of anterior tooth movement.
</formatted_text>
    <heading_path>Case: Removable appliance with Z-spring for lateral incisor crossbite</heading_path>
    <images>
      <img order="0" type="photo" path="L8.2 Removable Appliances Construction_figures/img_72e856ad63849ef1.webp" media="frame" source="slide" page="22" timestamp="00:16:51">
        <description>Clinical photograph of a dental study model showing an orthodontic appliance with a Z-spring (double helix cantilever) positioned labially to the upper incisors, along with clasps engaging the posterior teeth.</description>
      </img>
      <img order="1" type="photo" path="L8.2 Removable Appliances Construction_figures/img_1068bd656d8959ec.webp" media="frame" source="slide" page="23" timestamp="00:18:23">
        <description>A clinical photograph shows a double cantilever spring orthodontic appliance fabricated from wire, mounted on the labial surface of upper incisors on a dental model. The device features two horizontal arms extending laterally with circular loops at each end and a central vertical U-shaped loop structure, designed to move multiple teeth labially.</description>
      </img>
      <img order="2" type="photo" path="L8.2 Removable Appliances Construction_figures/img_000b7f1b9ba9b427.webp" media="frame" source="slide" page="24" timestamp="00:19:01">
        <description>Clinical photograph showing an intraoral appliance with a central expansion screw and clasps on the upper teeth.</description>
      </img>
    </images>
  </page>
  <page number="79" origin="cases">
    <text>## Case: Landing screw for anterior crossbite

### Question

**Scenario:** A dental study model fitted with a removable appliance featuring a landing screw.

**What's shown:** An appliance with a threaded screw and a piston-like active part underneath the acrylic, contacting an incisor in anterior crossbite.

**Consider:** The mechanism of action of the landing screw in correcting the crossbite.


### Answer

**Observations:**
- The incisor is in an anterior crossbite.
- The appliance features a landing screw with a piston-like component underneath the acrylic.

**Reasoning:** 
- The piston is in direct contact with the tooth to be moved labially.
- Activating the screw drives the piston forward, pushing the central incisors labially to correct the crossbite.

**Outcome:** The central incisors are moved forward to resolve the anterior crossbite.

**Takeaway:** A landing screw uses a piston mechanism under the acrylic to directly push teeth labially, effective for correcting anterior crossbites.

## Case: Labial bow for closing a diastema

### Question

**Scenario:** A close-up view of the upper part of a removable orthodontic appliance featuring a labial bow.

**What's shown:** A labial bow made of 0.7 or 0.8 mm stainless steel wire with loops extending from the canine to the distal part, touching all incisors.

**Consider:** How the labial bow can be activated to manage residual spaces or a diastema.


### Answer

**Observations:**
- The labial bow is made of 0.7 or 0.8 mm stainless steel wire.
- It features loops and touches all the incisors.
- There is a diastema or residual space present.

**Reasoning:** 
- If passive, the bow acts as a retainer.
- By activating the loops/springs, the bow can be used to close residual spaces or a diastema.
- Sufficient anchorage from the acrylic plate is required to allow the clasp to be activated effectively.

**Outcome:** The activated labial bow closes the diastema or residual space.

**Takeaway:** A labial bow can be activated to close spaces, but requires adequate anchorage from the acrylic baseplate to function effectively.

## Case: Roberts retractor and modified hollow clasp

### Question

**Scenario:** Clinical and intraoral photographs showing a Roberts retractor appliance and a variant of a hollow clasp.

**What's shown:** A Roberts retractor made of 0.5 mm stainless steel wire, and a clasp with a double loop on the canine.

**Consider:** The advantages, limitations, and patient instructions required for these specific clasp designs.


### Answer

**Observations:**
- The Roberts retractor uses 0.5 mm stainless steel wire.
- The modified hollow clasp features a double loop on the canine instead of a single loop.

**Reasoning:** 
- The 0.5 mm wire in the Roberts retractor increases resilience and range of movement.
- However, the thin wire is prone to over-bending if the patient removes and inserts the appliance improperly, rendering it inactive.
- The double loop on the canine clasp improves retention compared to a single loop.

**Outcome:** The appliances provide effective retention and movement, provided the patient is well-instructed.

**Takeaway:** Thinner wires (0.5 mm) increase resilience but require careful patient instruction to prevent over-bending; double loops on clasps improve retention.
</text>
    <formatted_text>## Case: Landing screw for anterior crossbite

### Question

**Scenario:** A dental study model fitted with a removable appliance featuring a landing screw.

**What's shown:** An appliance with a threaded screw and a piston-like active part underneath the acrylic, contacting an incisor in anterior crossbite.

**Consider:** The mechanism of action of the landing screw in correcting the crossbite.


![](L8.2 Removable Appliances Construction_cases_attachments/img_96a61f1534452b8b.webp)
![](L8.2 Removable Appliances Construction_cases_attachments/img_2f895528852e5326.webp)
### Answer

**Observations:**
- The incisor is in an anterior crossbite.
- The appliance features a landing screw with a piston-like component underneath the acrylic.

**Reasoning:** 
- The piston is in direct contact with the tooth to be moved labially.
- Activating the screw drives the piston forward, pushing the central incisors labially to correct the crossbite.

**Outcome:** The central incisors are moved forward to resolve the anterior crossbite.

**Takeaway:** A landing screw uses a piston mechanism under the acrylic to directly push teeth labially, effective for correcting anterior crossbites.

## Case: Labial bow for closing a diastema

### Question

**Scenario:** A close-up view of the upper part of a removable orthodontic appliance featuring a labial bow.

**What's shown:** A labial bow made of 0.7 or 0.8 mm stainless steel wire with loops extending from the canine to the distal part, touching all incisors.

**Consider:** How the labial bow can be activated to manage residual spaces or a diastema.


![](L8.2 Removable Appliances Construction_cases_attachments/img_9b024caa4b4af078.webp)
### Answer

**Observations:**
- The labial bow is made of 0.7 or 0.8 mm stainless steel wire.
- It features loops and touches all the incisors.
- There is a diastema or residual space present.

**Reasoning:** 
- If passive, the bow acts as a retainer.
- By activating the loops/springs, the bow can be used to close residual spaces or a diastema.
- Sufficient anchorage from the acrylic plate is required to allow the clasp to be activated effectively.

**Outcome:** The activated labial bow closes the diastema or residual space.

**Takeaway:** A labial bow can be activated to close spaces, but requires adequate anchorage from the acrylic baseplate to function effectively.

## Case: Roberts retractor and modified hollow clasp

### Question

**Scenario:** Clinical and intraoral photographs showing a Roberts retractor appliance and a variant of a hollow clasp.

**What's shown:** A Roberts retractor made of 0.5 mm stainless steel wire, and a clasp with a double loop on the canine.

**Consider:** The advantages, limitations, and patient instructions required for these specific clasp designs.


![](L8.2 Removable Appliances Construction_cases_attachments/img_6dddae70b122c74f.webp)
![](L8.2 Removable Appliances Construction_cases_attachments/img_5cbf6948f8dd743a.webp)
### Answer

**Observations:**
- The Roberts retractor uses 0.5 mm stainless steel wire.
- The modified hollow clasp features a double loop on the canine instead of a single loop.

**Reasoning:** 
- The 0.5 mm wire in the Roberts retractor increases resilience and range of movement.
- However, the thin wire is prone to over-bending if the patient removes and inserts the appliance improperly, rendering it inactive.
- The double loop on the canine clasp improves retention compared to a single loop.

**Outcome:** The appliances provide effective retention and movement, provided the patient is well-instructed.

**Takeaway:** Thinner wires (0.5 mm) increase resilience but require careful patient instruction to prevent over-bending; double loops on clasps improve retention.
</formatted_text>
    <heading_path>Case: Landing screw for anterior crossbite</heading_path>
    <images>
      <img order="0" type="photo" path="L8.2 Removable Appliances Construction_figures/img_96a61f1534452b8b.webp" media="frame" source="slide" page="25" timestamp="00:19:51">
        <description>Clinical photograph showing a dental study model fitted with an orthodontic appliance. A Landin screw (piston screw) is visible in the anterior region, connected to wire loops extending towards the incisors to facilitate labial movement.</description>
      </img>
      <img order="1" type="photo" path="L8.2 Removable Appliances Construction_figures/img_2f895528852e5326.webp" media="frame" source="slide" page="25" timestamp="00:19:51">
        <description>Clinical photo: A close-up view of a threaded metallic orthodontic screw (Landin screw) attached to the labial surface of an upper incisor tooth. The device features a piston-like mechanism with a small protruding shaft, illustrating the hardware used for moving teeth.</description>
      </img>
      <img order="2" type="photo" path="L8.2 Removable Appliances Construction_figures/img_9b024caa4b4af078.webp" media="frame" source="slide" page="26" timestamp="00:20:45">
        <description>Clinical photo: A close-up view of the upper anterior teeth fitted with a conventional labial bow appliance. The wire component is shown spanning across the facial surfaces of the incisors, illustrating the device described in the text.</description>
      </img>
      <img order="3" type="photo" path="L8.2 Removable Appliances Construction_figures/img_6dddae70b122c74f.webp" media="frame" source="slide" page="27" timestamp="00:21:55">
        <description>Clinical photo showing a Roberts retractor appliance attached to the maxillary teeth. The device consists of wire loops and tubing positioned anteriorly to retract proclined incisors, as described in the accompanying text.</description>
      </img>
      <img order="4" type="photo" path="L8.2 Removable Appliances Construction_figures/img_5cbf6948f8dd743a.webp" media="frame" source="slide" page="27" timestamp="00:21:55">
        <description>Clinical intraoral photograph showing a Roberts retractor appliance in the maxillary arch, with wire loops engaging the first molars and tubing visible on the buccal aspect.</description>
      </img>
    </images>
  </page>
  <page number="80" origin="cases">
    <text>## Case: Incisor retraction using elastics

### Question

**Scenario:** A clinical photograph showing an orthodontic appliance with a labial bow modified for elastics.

**What's shown:** An appliance with a clasp featuring a distal bend, allowing an intraoral latex elastic to be stretched across the anterior teeth.

**Consider:** The mechanism of retraction and the potential risks associated with this design.


### Answer

**Observations:**
- The clasp has a distal bend to hold an intraoral latex elastic.
- The elastic is stretched across the incisors.

**Reasoning:** 
- Stretching the elastic applies force to retract the incisors.
- There is a risk of the elastic sliding and hurting the patient's soft tissues.
- The patient must be able to place the elastic properly.

**Outcome:** The incisors are retracted using the elastic force.

**Takeaway:** Elastics can be used for incisor retraction on a removable appliance, but require close follow-up and patient instruction to prevent soft tissue injury from slipping.

## Case: Space regaining for a mesially drifted first molar

### Question

**Scenario:** A removable orthodontic appliance featuring a modified Z-spring with the active part in the proximal area.

**What's shown:** An appliance with a helix and an active proximal part designed to engage a first molar that has drifted mesially following the early loss of a primary molar.

**Consider:** The design considerations and limitations of using a removable appliance to distalize a molar and regain space for a premolar.


### Answer

**Observations:**
- The first molar has drifted mesially due to the early loss of a primary molar.
- The premolar cannot erupt due to lack of space.
- The appliance uses a modified Z-spring with a helix and proximal active part.

**Reasoning:** 
- Activating the helix moves the first molar distally to regain space for the premolar to erupt.
- Moving a molar backwards requires significant anchorage.
- In the upper arch, the acrylic plate can cover the palate for anchorage. In the lower arch, the plate must be thinner due to the tongue, requiring different clasps to compensate and increase anchorage and retention.
- Limitations include the inability to regain more than 2 mm, especially if the adjacent second molar has also drifted forward and blocks the movement.

**Outcome:** The first molar is moved distally to open space for the premolar, within the limitations of the appliance.

**Takeaway:** Removable appliances can distalize mesially drifted molars to regain space, but require careful anchorage design and are limited in the amount of space that can be regained (maximum 2 mm).

## Case: Orthodontic appliance clasp interfering with canine eruption

### Question

**Scenario:** An orthodontic case involving a removable appliance and an erupting canine is presented for design evaluation.

**What's shown:** A radiograph of a dental arch with a wire orthodontic appliance in place.

**Consider:** How the current clasp design affects the erupting canine and what modifications should be made.


### Answer

**Observations:**
- The clasp is positioned in a way that prevents the canine from erupting.

**Reasoning:** If a canine is in eruption, the clasp design must be altered to avoid blocking its path. The clasp can be extended to the premolar area to avoid interference.

**Outcome:** The design must be changed to accommodate the erupting canine.

**Takeaway:** When designing a removable appliance, ensure that clasps do not impede the eruption path of developing teeth; modify the clasp extension if necessary.
</text>
    <formatted_text>## Case: Incisor retraction using elastics

### Question

**Scenario:** A clinical photograph showing an orthodontic appliance with a labial bow modified for elastics.

**What's shown:** An appliance with a clasp featuring a distal bend, allowing an intraoral latex elastic to be stretched across the anterior teeth.

**Consider:** The mechanism of retraction and the potential risks associated with this design.


![](L8.2 Removable Appliances Construction_cases_attachments/img_e87dd23a0fb1f6d6.webp)
### Answer

**Observations:**
- The clasp has a distal bend to hold an intraoral latex elastic.
- The elastic is stretched across the incisors.

**Reasoning:** 
- Stretching the elastic applies force to retract the incisors.
- There is a risk of the elastic sliding and hurting the patient's soft tissues.
- The patient must be able to place the elastic properly.

**Outcome:** The incisors are retracted using the elastic force.

**Takeaway:** Elastics can be used for incisor retraction on a removable appliance, but require close follow-up and patient instruction to prevent soft tissue injury from slipping.

## Case: Space regaining for a mesially drifted first molar

### Question

**Scenario:** A removable orthodontic appliance featuring a modified Z-spring with the active part in the proximal area.

**What's shown:** An appliance with a helix and an active proximal part designed to engage a first molar that has drifted mesially following the early loss of a primary molar.

**Consider:** The design considerations and limitations of using a removable appliance to distalize a molar and regain space for a premolar.


![](L8.2 Removable Appliances Construction_cases_attachments/img_bbb1431c5a693e43.webp)
![](L8.2 Removable Appliances Construction_cases_attachments/img_96acc732e89596e9.webp)
### Answer

**Observations:**
- The first molar has drifted mesially due to the early loss of a primary molar.
- The premolar cannot erupt due to lack of space.
- The appliance uses a modified Z-spring with a helix and proximal active part.

**Reasoning:** 
- Activating the helix moves the first molar distally to regain space for the premolar to erupt.
- Moving a molar backwards requires significant anchorage.
- In the upper arch, the acrylic plate can cover the palate for anchorage. In the lower arch, the plate must be thinner due to the tongue, requiring different clasps to compensate and increase anchorage and retention.
- Limitations include the inability to regain more than 2 mm, especially if the adjacent second molar has also drifted forward and blocks the movement.

**Outcome:** The first molar is moved distally to open space for the premolar, within the limitations of the appliance.

**Takeaway:** Removable appliances can distalize mesially drifted molars to regain space, but require careful anchorage design and are limited in the amount of space that can be regained (maximum 2 mm).

## Case: Orthodontic appliance clasp interfering with canine eruption

### Question

**Scenario:** An orthodontic case involving a removable appliance and an erupting canine is presented for design evaluation.

**What's shown:** A radiograph of a dental arch with a wire orthodontic appliance in place.

**Consider:** How the current clasp design affects the erupting canine and what modifications should be made.


![](L8.2 Removable Appliances Construction_cases_attachments/img_538c0f3c0051907c.webp)
### Answer

**Observations:**
- The clasp is positioned in a way that prevents the canine from erupting.

**Reasoning:** If a canine is in eruption, the clasp design must be altered to avoid blocking its path. The clasp can be extended to the premolar area to avoid interference.

**Outcome:** The design must be changed to accommodate the erupting canine.

**Takeaway:** When designing a removable appliance, ensure that clasps do not impede the eruption path of developing teeth; modify the clasp extension if necessary.
</formatted_text>
    <heading_path>Case: Incisor retraction using elastics</heading_path>
    <images>
      <img order="0" type="figure" path="L8.2 Removable Appliances Construction_figures/img_e87dd23a0fb1f6d6.webp" media="frame" source="slide" page="28" timestamp="00:23:46">
        <description>Baseplate trimmed Elastic Labial bow cut and bent A clinical photograph showing an orthodontic appliance in the mouth, featuring a labial bow that has been cut and bent to form hooks for elastic attachment. Green arrows point to specific components, identifying the trimmed baseplate and the elastic band stretched across the arch.</description>
      </img>
      <img order="1" type="figure" path="L8.2 Removable Appliances Construction_figures/img_bbb1431c5a693e43.webp" media="frame" source="slide" page="29" timestamp="00:24:37">
        <description>A close-up photograph showing a bent wire orthodontic spring attached to a dental model. The spring features a central vertical section and a lower looped structure, positioned against the palatal surfaces of the teeth.</description>
      </img>
      <img order="2" type="photo" path="L8.2 Removable Appliances Construction_figures/img_96acc732e89596e9.webp" media="frame" source="slide" page="29" timestamp="00:24:37">
        <description>Clinical photo of a removable orthodontic appliance featuring a wire component with a looped tip, identified as a Palatal Finger Spring.</description>
      </img>
      <img order="3" type="figure" path="L8.2 Removable Appliances Construction_figures/img_538c0f3c0051907c.webp" media="frame" source="slide" page="60" timestamp="00:52:02">
        <description>A black-and-white radiograph showing a dental arch with a wire framework (likely an orthodontic appliance or retainer) positioned over the teeth. The image illustrates how the metal wires and loops of the framework sit in close proximity to the tooth structures, visually demonstrating the potential for the device to physically obstruct or prevent the eruption of a tooth.</description>
      </img>
    </images>
  </page>
  <page number="81" origin="cases">
    <text>## Case: Upper removable appliance with unadapted Adams clasp

### Question

**Scenario:** A maxillary dental cast with a removable orthodontic appliance is evaluated for fit and retention.

**What's shown:** A clinical photograph of a maxillary dental cast showing an Adams clasp on the appliance.

**Consider:** The adaptation of the Adams clasp and its effect on the appliance's retention.


### Answer

**Observations:**
- The bridge or buccal face of the Adams clasp on the left side is not adapted and sits far away from the tooth.
- The right side appears to be adequately adapted.

**Reasoning:** An unadapted clasp provides no retention. Because the left side of the clasp is not in contact with the tooth, the left side of the upper removable appliance will not achieve enough retention, and the plate will not stay in position.

**Outcome:** The appliance will lack retention on the left side and fail to stay in place.

**Takeaway:** Proper adaptation of the Adams clasp bridge to the tooth surface is critical for achieving adequate retention of a removable appliance.

## Case: Removable appliance design with labial bow interfering with canine retraction spring

### Question

**Scenario:** A wire orthodontic removable appliance is being evaluated for potential design interferences during canine retraction.

**What's shown:** A close-up clinical photograph of a wire orthodontic appliance featuring a labial bow and a spring.

**Consider:** The interaction between the labial bow and the spring used for canine retraction, and how to resolve any interference.


### Answer

**Observations:**
- A labial bow is present to increase retention.
- A spring is intended to retract the canine distally.
- The regular labial bow rests on the distal aspect of the canine, preventing the spring from being activated.

**Reasoning:** If the labial bow contacts the distal face of the canine, it blocks the activation of the retraction spring. To resolve this, the spring must be kept in place to move the canine distally, and the labial bow must be modified so it does not contact the distal face of the canine.

**Outcome:** The labial bow design must be changed to clear the distal face of the canine to allow spring activation.

**Takeaway:** When designing a removable appliance for canine retraction, ensure that the retentive labial bow does not interfere with the activation path of the retraction spring.</text>
    <formatted_text>## Case: Upper removable appliance with unadapted Adams clasp

### Question

**Scenario:** A maxillary dental cast with a removable orthodontic appliance is evaluated for fit and retention.

**What's shown:** A clinical photograph of a maxillary dental cast showing an Adams clasp on the appliance.

**Consider:** The adaptation of the Adams clasp and its effect on the appliance's retention.


![](L8.2 Removable Appliances Construction_cases_attachments/img_03909596728f6683.webp)
### Answer

**Observations:**
- The bridge or buccal face of the Adams clasp on the left side is not adapted and sits far away from the tooth.
- The right side appears to be adequately adapted.

**Reasoning:** An unadapted clasp provides no retention. Because the left side of the clasp is not in contact with the tooth, the left side of the upper removable appliance will not achieve enough retention, and the plate will not stay in position.

**Outcome:** The appliance will lack retention on the left side and fail to stay in place.

**Takeaway:** Proper adaptation of the Adams clasp bridge to the tooth surface is critical for achieving adequate retention of a removable appliance.

## Case: Removable appliance design with labial bow interfering with canine retraction spring

### Question

**Scenario:** A wire orthodontic removable appliance is being evaluated for potential design interferences during canine retraction.

**What's shown:** A close-up clinical photograph of a wire orthodontic appliance featuring a labial bow and a spring.

**Consider:** The interaction between the labial bow and the spring used for canine retraction, and how to resolve any interference.


![](L8.2 Removable Appliances Construction_cases_attachments/img_ee6e114453d7ea10.webp)
![](L8.2 Removable Appliances Construction_cases_attachments/img_e68741ed8e2bd0c3.webp)
![](L8.2 Removable Appliances Construction_cases_attachments/img_25141903f22b36ef.webp)
### Answer

**Observations:**
- A labial bow is present to increase retention.
- A spring is intended to retract the canine distally.
- The regular labial bow rests on the distal aspect of the canine, preventing the spring from being activated.

**Reasoning:** If the labial bow contacts the distal face of the canine, it blocks the activation of the retraction spring. To resolve this, the spring must be kept in place to move the canine distally, and the labial bow must be modified so it does not contact the distal face of the canine.

**Outcome:** The labial bow design must be changed to clear the distal face of the canine to allow spring activation.

**Takeaway:** When designing a removable appliance for canine retraction, ensure that the retentive labial bow does not interfere with the activation path of the retraction spring.</formatted_text>
    <heading_path>Case: Upper removable appliance with unadapted Adams clasp</heading_path>
    <images>
      <img order="0" type="photo" path="L8.2 Removable Appliances Construction_figures/img_03909596728f6683.webp" media="frame" source="slide" page="61" timestamp="00:52:35">
        <description>Clinical photo showing a maxillary dental cast with a removable partial denture framework. The image illustrates the placement of an Adams clasp on a posterior tooth, specifically highlighting how the connecting bridge arches over the gingival tissue and adjacent teeth.</description>
      </img>
      <img order="1" type="photo" path="L8.2 Removable Appliances Construction_figures/img_ee6e114453d7ea10.webp" media="frame" source="slide" page="62" timestamp="00:53:19">
        <description>A close-up clinical photograph shows a wire orthodontic appliance fitted over teeth. A green arrow points to the vertical loop of the labial bow, illustrating its position relative to the canine tooth.</description>
      </img>
      <img order="2" type="photo" path="L8.2 Removable Appliances Construction_figures/img_e68741ed8e2bd0c3.webp" media="frame" source="slide" page="63" timestamp="00:54:20">
        <description>b A photograph of a transparent orthodontic removable appliance with wire clasps and an expansion screw mechanism embedded in the midline. The image illustrates a common design failure where the screw is positioned incorrectly, causing it to displace the appliance rather than expand it.</description>
      </img>
      <img order="3" type="photo" path="L8.2 Removable Appliances Construction_figures/img_25141903f22b36ef.webp" media="frame" source="slide" page="63" timestamp="00:54:20">
        <description>a A lateral cephalometric radiograph showing a patient wearing a removable orthodontic appliance with metal clasps and wires. A dark, cross-shaped object (likely a screw or marker) is superimposed over the central region of the appliance, illustrating its position relative to the teeth and jaw.</description>
      </img>
    </images>
  </page>
  <footnotes>[^1]: Original PDF page 1: [[L8.2 Removable Appliances Construction.pdf#page=1|L8.2 Removable Appliances Construction, p.1]]
[^2]: Original PDF page 2: [[L8.2 Removable Appliances Construction.pdf#page=2|L8.2 Removable Appliances Construction, p.2]]
[^3]: Original PDF page 3: [[L8.2 Removable Appliances Construction.pdf#page=3|L8.2 Removable Appliances Construction, p.3]]
[^4]: Original PDF page 4: [[L8.2 Removable Appliances Construction.pdf#page=4|L8.2 Removable Appliances Construction, p.4]]
[^5]: Original PDF page 5: [[L8.2 Removable Appliances Construction.pdf#page=5|L8.2 Removable Appliances Construction, p.5]]
[^6]: Original PDF page 6: [[L8.2 Removable Appliances Construction.pdf#page=6|L8.2 Removable Appliances Construction, p.6]]
[^7]: Original PDF page 7: [[L8.2 Removable Appliances Construction.pdf#page=7|L8.2 Removable Appliances Construction, p.7]]
[^8]: Original PDF page 8: [[L8.2 Removable Appliances Construction.pdf#page=8|L8.2 Removable Appliances Construction, p.8]]
[^9]: Original PDF page 9: [[L8.2 Removable Appliances Construction.pdf#page=9|L8.2 Removable Appliances Construction, p.9]]
[^10]: Original PDF page 10: [[L8.2 Removable Appliances Construction.pdf#page=10|L8.2 Removable Appliances Construction, p.10]]
[^11]: Original PDF page 11: [[L8.2 Removable Appliances Construction.pdf#page=11|L8.2 Removable Appliances Construction, p.11]]
[^12]: Original PDF page 12: [[L8.2 Removable Appliances Construction.pdf#page=12|L8.2 Removable Appliances Construction, p.12]]
[^13]: Original PDF page 13: [[L8.2 Removable Appliances Construction.pdf#page=13|L8.2 Removable Appliances Construction, p.13]]
[^14]: Original PDF page 14: [[L8.2 Removable Appliances Construction.pdf#page=14|L8.2 Removable Appliances Construction, p.14]]
[^15]: Original PDF page 15: [[L8.2 Removable Appliances Construction.pdf#page=15|L8.2 Removable Appliances Construction, p.15]]
[^16]: Original PDF page 16: [[L8.2 Removable Appliances Construction.pdf#page=16|L8.2 Removable Appliances Construction, p.16]]
[^17]: Original PDF page 17: [[L8.2 Removable Appliances Construction.pdf#page=17|L8.2 Removable Appliances Construction, p.17]]
[^18]: Original PDF page 18: [[L8.2 Removable Appliances Construction.pdf#page=18|L8.2 Removable Appliances Construction, p.18]]
[^19]: Original PDF page 19: [[L8.2 Removable Appliances Construction.pdf#page=19|L8.2 Removable Appliances Construction, p.19]]
[^20]: Original PDF page 20: [[L8.2 Removable Appliances Construction.pdf#page=20|L8.2 Removable Appliances Construction, p.20]]
[^21]: Original PDF page 21: [[L8.2 Removable Appliances Construction.pdf#page=21|L8.2 Removable Appliances Construction, p.21]]
[^22]: Original PDF page 22: [[L8.2 Removable Appliances Construction.pdf#page=22|L8.2 Removable Appliances Construction, p.22]]
[^23]: Original PDF page 23: [[L8.2 Removable Appliances Construction.pdf#page=23|L8.2 Removable Appliances Construction, p.23]]
[^24]: Original PDF page 24: [[L8.2 Removable Appliances Construction.pdf#page=24|L8.2 Removable Appliances Construction, p.24]]
[^25]: Original PDF page 25: [[L8.2 Removable Appliances Construction.pdf#page=25|L8.2 Removable Appliances Construction, p.25]]
[^26]: Original PDF page 26: [[L8.2 Removable Appliances Construction.pdf#page=26|L8.2 Removable Appliances Construction, p.26]]
[^27]: Original PDF page 27: [[L8.2 Removable Appliances Construction.pdf#page=27|L8.2 Removable Appliances Construction, p.27]]
[^28]: Original PDF page 28: [[L8.2 Removable Appliances Construction.pdf#page=28|L8.2 Removable Appliances Construction, p.28]]
[^29]: Original PDF page 29: [[L8.2 Removable Appliances Construction.pdf#page=29|L8.2 Removable Appliances Construction, p.29]]
[^30]: Original PDF page 30: [[L8.2 Removable Appliances Construction.pdf#page=30|L8.2 Removable Appliances Construction, p.30]]
[^31]: Original PDF page 31: [[L8.2 Removable Appliances Construction.pdf#page=31|L8.2 Removable Appliances Construction, p.31]]
[^32]: Original PDF page 32: [[L8.2 Removable Appliances Construction.pdf#page=32|L8.2 Removable Appliances Construction, p.32]]
[^33]: Original PDF page 33: [[L8.2 Removable Appliances Construction.pdf#page=33|L8.2 Removable Appliances Construction, p.33]]
[^34]: Original PDF page 34: [[L8.2 Removable Appliances Construction.pdf#page=34|L8.2 Removable Appliances Construction, p.34]]
[^35]: Original PDF page 35: [[L8.2 Removable Appliances Construction.pdf#page=35|L8.2 Removable Appliances Construction, p.35]]
[^36]: Original PDF page 36: [[L8.2 Removable Appliances Construction.pdf#page=36|L8.2 Removable Appliances Construction, p.36]]
[^37]: Original PDF page 37: [[L8.2 Removable Appliances Construction.pdf#page=37|L8.2 Removable Appliances Construction, p.37]]
[^38]: Original PDF page 38: [[L8.2 Removable Appliances Construction.pdf#page=38|L8.2 Removable Appliances Construction, p.38]]
[^39]: Original PDF page 39: [[L8.2 Removable Appliances Construction.pdf#page=39|L8.2 Removable Appliances Construction, p.39]]
[^40]: Original PDF page 40: [[L8.2 Removable Appliances Construction.pdf#page=40|L8.2 Removable Appliances Construction, p.40]]
[^41]: Original PDF page 41: [[L8.2 Removable Appliances Construction.pdf#page=41|L8.2 Removable Appliances Construction, p.41]]
[^42]: Original PDF page 42: [[L8.2 Removable Appliances Construction.pdf#page=42|L8.2 Removable Appliances Construction, p.42]]
[^43]: Original PDF page 43: [[L8.2 Removable Appliances Construction.pdf#page=43|L8.2 Removable Appliances Construction, p.43]]
[^44]: Original PDF page 44: [[L8.2 Removable Appliances Construction.pdf#page=44|L8.2 Removable Appliances Construction, p.44]]
[^45]: Original PDF page 45: [[L8.2 Removable Appliances Construction.pdf#page=45|L8.2 Removable Appliances Construction, p.45]]
[^46]: Original PDF page 46: [[L8.2 Removable Appliances Construction.pdf#page=46|L8.2 Removable Appliances Construction, p.46]]
[^47]: Original PDF page 47: [[L8.2 Removable Appliances Construction.pdf#page=47|L8.2 Removable Appliances Construction, p.47]]
[^48]: Original PDF page 48: [[L8.2 Removable Appliances Construction.pdf#page=48|L8.2 Removable Appliances Construction, p.48]]
[^49]: Original PDF page 49: [[L8.2 Removable Appliances Construction.pdf#page=49|L8.2 Removable Appliances Construction, p.49]]
[^50]: Original PDF page 50: [[L8.2 Removable Appliances Construction.pdf#page=50|L8.2 Removable Appliances Construction, p.50]]
[^51]: Original PDF page 51: [[L8.2 Removable Appliances Construction.pdf#page=51|L8.2 Removable Appliances Construction, p.51]]
[^52]: Original PDF page 52: [[L8.2 Removable Appliances Construction.pdf#page=52|L8.2 Removable Appliances Construction, p.52]]
[^53]: Original PDF page 53: [[L8.2 Removable Appliances Construction.pdf#page=53|L8.2 Removable Appliances Construction, p.53]]
[^54]: Original PDF page 54: [[L8.2 Removable Appliances Construction.pdf#page=54|L8.2 Removable Appliances Construction, p.54]]
[^55]: Original PDF page 55: [[L8.2 Removable Appliances Construction.pdf#page=55|L8.2 Removable Appliances Construction, p.55]]
[^56]: Original PDF page 56: [[L8.2 Removable Appliances Construction.pdf#page=56|L8.2 Removable Appliances Construction, p.56]]
[^57]: Original PDF page 57: [[L8.2 Removable Appliances Construction.pdf#page=57|L8.2 Removable Appliances Construction, p.57]]
[^58]: Original PDF page 58: [[L8.2 Removable Appliances Construction.pdf#page=58|L8.2 Removable Appliances Construction, p.58]]
[^59]: Original PDF page 59: [[L8.2 Removable Appliances Construction.pdf#page=59|L8.2 Removable Appliances Construction, p.59]]
[^60]: Original PDF page 60: [[L8.2 Removable Appliances Construction.pdf#page=60|L8.2 Removable Appliances Construction, p.60]]
[^61]: Original PDF page 61: [[L8.2 Removable Appliances Construction.pdf#page=61|L8.2 Removable Appliances Construction, p.61]]
[^62]: Original PDF page 62: [[L8.2 Removable Appliances Construction.pdf#page=62|L8.2 Removable Appliances Construction, p.62]]
[^63]: Original PDF page 63: [[L8.2 Removable Appliances Construction.pdf#page=63|L8.2 Removable Appliances Construction, p.63]]
[^64]: Original PDF page 64: [[L8.2 Removable Appliances Construction.pdf#page=64|L8.2 Removable Appliances Construction, p.64]]
[^65]: Original PDF page 65: [[L8.2 Removable Appliances Construction.pdf#page=65|L8.2 Removable Appliances Construction, p.65]]
[^66]: Original PDF page 66: [[L8.2 Removable Appliances Construction.pdf#page=66|L8.2 Removable Appliances Construction, p.66]]
[^67]: Original PDF page 67: [[L8.2 Removable Appliances Construction.pdf#page=67|L8.2 Removable Appliances Construction, p.67]]
[^68]: Original PDF page 68: [[L8.2 Removable Appliances Construction.pdf#page=68|L8.2 Removable Appliances Construction, p.68]]
[^69]: Original PDF page 69: [[L8.2 Removable Appliances Construction.pdf#page=69|L8.2 Removable Appliances Construction, p.69]]
[^70]: Original PDF page 70: [[L8.2 Removable Appliances Construction.pdf#page=70|L8.2 Removable Appliances Construction, p.70]]
[^71]: Original PDF page 71: [[L8.2 Removable Appliances Construction.pdf#page=71|L8.2 Removable Appliances Construction, p.71]]
[^72]: Original PDF page 72: [[L8.2 Removable Appliances Construction.pdf#page=72|L8.2 Removable Appliances Construction, p.72]]
[^73]: Original PDF page 73: [[L8.2 Removable Appliances Construction.pdf#page=73|L8.2 Removable Appliances Construction, p.73]]
[^74]: Original PDF page 74: [[L8.2 Removable Appliances Construction.pdf#page=74|L8.2 Removable Appliances Construction, p.74]]
[^75]: Original PDF page 75: [[L8.2 Removable Appliances Construction.pdf#page=75|L8.2 Removable Appliances Construction, p.75]]
[^76]: Original PDF page 76: [[L8.2 Removable Appliances Construction.pdf#page=76|L8.2 Removable Appliances Construction, p.76]]
[^77]: Original PDF page 77: [[L8.2 Removable Appliances Construction.pdf#page=77|L8.2 Removable Appliances Construction, p.77]]</footnotes>
</document>
